SpinalStim Classifications

• Product Family Name: Orthofix PEMF Device
• Internally powered equipment
• The service life of the non-replaceable lithium-ion battery is 2.5 years.
• This device generates a non-ionizing pulsed electromagnetic field with
an intensity of approximately 2 Gauss and frequency components in the
1Hz-50KHz range. This field is distributed within and near the treatment coil.
• Type BF applied part. The applied part is the treatment coil with
integrated control unit.
• IEC 60529 enclosure rating: IP22. IP22 means the enclosure provides protection
from solid objects > 12.5mm and dripping liquids when tilted 15° from normal
use. It is recommended you keep the unit dry.
• Shelf life for equipment: 1 year
• Mode of operation: intermittent operation
• This device is non-sterile. It does not require sterilization.
• Equipment not suitable for use in the presence of a flammable
anesthetic mixture with air or nitrous oxide.
• The power supply is considered double insulated with Class II
construction throughout.
• Power supply ratings:
Orthofix # 20110412:
Input: 100-240VAC, 50-60Hz, 200mA Input: 100-240VAC, 50-60Hz, 150-350mA
Output Voltage: 5VDC, 1.3A

Compliance Statements

This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
IMPORTANT! Changes or modifications not expressly approved by Orthofix, Inc. could
void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
Orthofix # 20114794:
Output Voltage: 5VDC, 2.4A
17