Lowara Ecocirc Serie Instrucciones Para La Instalación Y El Uso página 19

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 40
3 x short + 1 x long
4 x short
2 x short + 1 x long +1 x
short
2 x short + 2 x long
1 x short + 1 x long + 1 x
short + 1 x long
1 x short + 1 x long + 2 x
short
1 x very short + 1 x long
pause
Proceed as follows for other faults:
Fault
Pump is making
loud noises
Note regarding excessive temperatures:
In order to protect the electronics from temperatures that are dangerously
high, the electronic control system monitors its own temperature. If the
measured temperature is too high the pump speed is reduced. If the
• Voltage too low / too
high
• Temperature too high
• Self test error
• Excess current error
• Unstable operation
• Start up error
• Air purge function
Cause
• Not thoroughly vented
• Foreign objects in
pump
• Worn out bearing
19
• Check mains voltage
• Pump restarts
automatically
(see the notes below)
• Determine max. system
temperature
• Please contact
authorized service
center or point of
purchase
• See section 8
Maintenance/
Disassembly"
• See section 8
Maintenance/
Disassembly"
• Rotor blocked
• See section 8
Maintenance/
Disassembly"
• Pump runs in air purge
function / color means
mode selected
Solution
• See section 7.2
"Getting
started"
• See section 8
"Maintenance/
Disassembly"
• Replace pump