Health Zenith DualBrite SL-5316 Manual De Instrucciones página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
it will detect motion. When first turned on or when
switching modes wait 1
❒ Turn the RANGE control to the mid position, D
to OFF and the ON-TIME control to the TEST
position.
MAX
ON - TIME
MIN
TEST 1 5 2 0
RANGE
MINUTES
Bottom of Sensor
Avoid aiming the sensor at:
• Objects that change temperature rapidly, such as heat-
ing vents and air conditioners. These heat sources
could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light may
trigger the shut-off feature. Do not point other lights at
the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m) (30.5 m)
Maximum Range
The detector is less sensitive to motion directly towards it.
Motion
Least Sensitive
595-5109-13
/
minute warm up period before
1
2
/
minutes.
1
2
ual
DUAL BRITE
OFF 3 6 DUSK TO
HOUR DAWN
100 ft.
Boosted
Maximum
Coverage Angle
Motion
Sensor
Most Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently rotate
the sensor.
❒ Walk through the coverage area
noting where you are when the
lights turn on. Move the sensor
head up, down, or sideways to
change the coverage area. Keep
B
®
rite
the sensor at least 1" (2.5 cm)
away from the lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head's aim
by tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of T IME you want
the lights to stay on after motion is
detected (1, 5, or 20 minutes).
❒ Set the D
ual
dusk you want the lights on at low level (Off, 3, 6 Hrs.,
Dusk-to-Dawn).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
Sensing Angle . . . . . . Up to 240°
Electrical Load . . . . . . Up to 500 Watts Maximum Incan-
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
240°
Time Delay . . . . . . . . 1, 5, 20 minutes
D
B
Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn
®
ual
rite
HeathCo LLC reserves the right to discontinue products
and to change specifications at any time without incurring
any obligation to incorporate new features in products
previously sold.
3
Down for Short
Higher for Long
B
switch to the amount of time after
®
rite
(30.5 m) with Range Boost. [varies
with surrounding temperature]
descent
MODE
Clamp
Screw
Ball
Joint
Aim Sensor
Coverage
Aim Sensor
Coverage

Publicidad

Tabla de contenido
loading

Tabla de contenido