Siemens SITRANS LVS100 Instrucciones De Operación página 12

Ocultar thumbs Ver también para SITRANS LVS100:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SITRANS LVS100/200 is normally mounted into the vessel top for full detection, or
through the tank wall at the detection level, for full, demand, or empty detection.
*
max. deviation
from vertical
max. length L
4 m
45º
1.2 m
>45º
0.6 m
Page EN-10
SITRANS LVS100/200 – INSTRUCTION MANUAL
Cable
extension
*
version
L
Rigid extension with
sliding sleeve
Protection in case of
high material loading.
Use angle mounting for flowing
material only.
If angle mounting is required
with high material loading,
customer-supplied protection
from falling material must be in
place.
Position tines vertically
to avoid product build-
up: use a 50 mm open-
end wrench to turn the
process connection
until the tine
orientation marking
faces up or down.
Cable gland faces
downward to avoid
water penetration.
Tine orientation
marking facing
sideways.
7ML19985FT63