SP EC I FI C AT IO N S
Electrical Requirements
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply within the shaded area shown in
the installation illustration on the following page. A separate
circuit servicing only this appliance is required. A ground
fault circuit interrupter (GFCI) is not recommended and may
cause interruption of operation.
E L E C TR I CA L R E Q U I R E ME N T S
Electrical Supply
220–240 V AC, 50/60 Hz
Service
Receptacle
grounding-type (earthed)
Power Cord
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off, there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses, and/or
relays according to EN60335.
1.9 A
1.8 m
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions
Gas Supply
Installation must conform with local codes.
Locate the gas supply within the shaded area shown in the
installation illustration on the following page.
The rangetop is equipped for use with natural or liquid pro-
pane (LP) gas. The product rating plate has information on
the type of gas that should be used. For rating plate loca-
tion, refer to the illustration below. If this information does
not agree with the type of gas available, check with the local
gas supplier. The gas pressure regulator is built into the unit.
G AS R EQ U I R EMEN T S
N AT U RA L GA S
Supply Pressure
Min Line Pressure
Max Regulator Pressure
34.9 mb
L P GA S
Supply Pressure
Min Line Pressure
Max Regulator Pressure
34.9 mb
RATING PLATE
Rating plate location
The sealed burner rangetop must be connected to a regu-
lated gas supply. The supply line must be equipped with
an approved external gas shut-off valve located near the
rangetop in an accessible location. Do not block access to
the shut-off valve. Refer to the illustration below.
A compatible ISO 7-1 gas inlet thread is provided on all
units. Contact your authorized Wolf dealer if an ISO 228-1
or other gas inlet thread is required. Pipe joint compounds,
suitable for use with LP gas should be used. For LP gas,
piping or tubing size can be 13 mm minimum. LP gas sup-
pliers usually determine the size and materials used on the
system.
WC
12.5 mb
If local codes permit, a flexible metal appliance connector
17.5 mb
is recommended for connecting this rangetop to the gas
3.5 kPa
,
supply line. Do not kink or damage the flexible connector
when moving the rangetop.
W C
25 mb
If rigid pipe is used as a gas supply line, a combination of
27.4 mb
pipe fittings must be used to obtain an in-line connection to
3.5 kPa
,
the rangetop. All strains must be removed from the supply
and gas lines so the rangetop will be level and in line.
Wolf natural gas rangetops will function up to 3124 m in
altitude without adjustment and LP gas rangetops up to
2621 m. If the installation exceeds these elevations, contact
your authorized Wolf dealer for a high altitude conversion
kit.
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve
wolfappliance.com
|