Topping up the oil
To ensure that the rivet gun remains operational for as long as possi-
ble, make sure that there is sufficient pneumatic oil in the appliance.
The following options are available:
♦
Attach a maintenance unit with an oiler to the compressor.
♦
Install a fitted oiler into the compressed air line or the compressor.
♦
Manually add 3–5 drops of pneumatic oil from the supplied oil
container
operation.
♦
When opening the oil container
cap nut from the container. Use a pair of long-nosed pliers or
similar implement to remove the internal pipette.
♦
Turn it 180 °, replace it and screw it back in place with the cap nut.
♦
Use a needle or similar tool to poke a small hole into the tip of the
pipette to release oil.
Connecting to a compressed air source
NOTE
►
Before connecting the compressed air source,
–
the correct working pressure (3–6 bar) must be fully
reached
–
ensure that the trigger
♦
Remove the cover
♦
To seal the thread on the connecting nipple
of the sealing tape
screw the connecting nipple
│
GB │ IE
■
36
into the connecting nipple
from the compressed air supply
around it. Use the assembly spanner
every 15 minutes of
for the first time, remove the
is not pulled
, wrap 2 or 3 layers
into the compressed air supply
.
to