Commissioning/Start-Up; Order Of Starting Up Steps - Oase ProfiClear Premium Instrucciones De Uso

Ocultar thumbs Ver también para ProfiClear Premium:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 129
- GB -
6

Commissioning/start-up

Thoroughly clean the pond before starting up the filter system for the first time to ensure that it is not
overloaded by excessively soiled water. OASE recommends using the Pondovac pond vacuum cleaner
for cleaning the pond.
This cleaning measure is normally not necessary for newly installed ponds.
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Isolate the unit prior to reaching into the water and carrying out any work on the
unit. Secure the unit from being switched on inadvertantly.
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure:
Do not connect the unit to a dimmable power supply.
Do not operate the unit with a timer.
Attention! Never allow the rinsing pump to run dry!
Possible consequences: The rinsing pump will be destroyed.
Protective measures:
Check the water level at regular intervals. Ensure that the rinsing pump is always under water during
operation.
Do not switch on the control system until the container is flooded with water.
6.1

Order of starting up steps

Gravity fed system
G
How to proceed:
7.
1. Close the slide valve for the dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Remove the container cover.
4. Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
5. Open the slide valve at the inlet and outlet, if applicable, to fill the filter system with water.
6. Fill the pond until the maximum water level is reached.
7. Check the water level in the Drum Filter Module. Refer to the sticker with level markings on the
inside wall of the container.
Ideal water level: 115 mm below the top edge of the container
Permissible tolerance: -20 mm (135 mm below the top edge of the container)
Correct the installation if the minimum water level is not reached.
8. Check all pipes, hoses and their connections for leaks.
Expansion seals may leak initially until they have fully expanded on contact with water.
9. Fit the container cover.
The filter drum is stopped for safety reasons if the filter cover is lifted.
10. Switch on the control system and perform any necessary adjustments. (
11. Switch on the filter pumps and UVC clarifying unit in the Individual Module (if applicable).
12. Adjust the level detection device to the water level in the filter system. (
detection device)
If using filter starters (e.g. OASE BioKick), do not operate any UVC clarifying units for at least 24 hours
so as not to disturb the colonisation of the filter media by micro-organisms.
52
Operation)
Adjusting the level

Publicidad

Tabla de contenido
loading

Tabla de contenido