4.3

Correct electrical installation

Electrical installations must meet the national regulations and may only be carried out by a qualified
electrician.
A person is regarded as a qualified electrician, if, due to his/her vocational education, knowledge
and experience, he or she is capable of and authorised to judge and carry out the work
commissioned to him/her. This also includes the recognition of possible hazards and the adherence
to the pertinent regional and national standards, rules and regulations.
For your own safety, please consult a qualified electrician.
The unit may only be connected when the electrical data of the unit and the power supply coincide.
The unit data is to be found on the unit type plate or on the packaging, or in this manual.
Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current
protection device.
Extension cables and power distributors (e. g. outlet strips) must be suitable for outdoor use.
Ensure that the power connection cable cross section is not smaller than that of the rubber hoses
with the identification H07RN-F. Extension cables must meet DIN VDE 0620. requirements
Protect the plug connections from moisture.
Only plug the unit into a correctly fitted socket.
4.4

Safe operation

Never operate the unit if either the electrical cables or the housing are defective!
Do not carry or pull the unit by its electrical cable.
Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do
not present a tripping obstacle.
Only open the unit housing or its attendant components, when this is explicitly required in the
operating instructions.
Only execute work on the unit that is described in this manual. If problems cannot be overcome,
please contact an authorised customer service point or, when in doubt, the manufacturer.
Only use original spare parts and accessories for the unit.
Never carry out technical modifications to the unit.
The power connection cables cannot be replaced. When the cable is damaged, the unit or the
component needs to be disposed of.
Keep the socket and power plug dry.
Overvoltage in the mains could lead to operating malfunctions of the unit. For information, please
refer to chapter "Remedy of faults".
Do not breath in the spray from the rinsing device. The spray may contain harmful bacteria. When
the container cover is lifted up, the rinsing device continues operating.