System message
Functions that are still
available
20 cleaning cycles in
• Manual cleaning
Er33
succession
• Time-dependent cleaning
Possible cause
Remedy
Level detection device stuck or
Clean the level detection device to ensure that the
defective
mechanics operate freely, replace if necessary.
Screen elements heavily soiled
Clean/descale the screen elements (→ Removing/fitting a
screen element)
Rinsing pump not operating
• Clean the bottom of the container, clean the rinsing pump
(→ Cleaning the rinsing pump)
•
Check the pump connection
Rinsing nozzles clogged
Clean the rinsing nozzles
Filter drum not rotating
• Check the motor connection
• Check the rotating movement of the filter drum. To do so,
check the markings (1 - 8) on the filter drum to detect a
rotating movement.
Gravity fed systems only:
Water level is beneath the level
• Increase the water level of the pond
detection device
•
Use the OASE ProfiClear Guard refill system
Level detection device set too high
Adjust the level detection device (→ Setting the level
detection device)
Water level in the system too low:
• Excessive flow quantity (pump
• Reduce flow quantity (adjust pump capacity)
capacity too high)
• Water supply too low
• Select a larger pipe diameter for the water supply if
necessary
• Water inlet blocked
• Clean water inlet
Pump fed system only:
Level detection device set too low
Adjust the level detection device (→ Setting the level
detection device)
Water level in the system too high:
• Outlet pipes soiled
• Clean outlet pipes
• Outlet opening too small
• Enlarge outlet opening
• Excessive flow quantity (pump
• Reduce flow quantity (adjust pump capacity)
capacity too high)
- EN -
Resetting the system
message
Press
key for 5 s
65