quickly for 5sec and load is off to
confirm successful learning (See
FIG.20-C).
•
After learning procedure, the
detector returns to AUTO mode
with LED and load being off.
LED and load keep on 5sec
(the actual light level range
is 10 - 2000Lux)
www.grupotemper.com
NOTE
When the actual light level is out of
the range 10 - 2000Lux, detector will
learn 25sec, then the red LED flashes
quickly for 5sec. When the actual
light level is below 10Lux, Lux value
is set to 10Lux, or is above 2000Lux,
Lux value is set to 2000Lux.
Installer should be away from the
detector to avoid affecting the
luminous flux that reaches the
detector when learning Lux value.
LED flashes slowly for 25sec
& Load is off
W
LED flashes quickly for 5sec &
Load is off (the actual light
level range is out of 10 -
2000Lux)
LED and load off
Detector switches to AUTO
FIG.20-C
KDP1 360 FP
Presence detector
W
W
W
Instructions manual |
35