Burners Technical Data Table; Rules For Converting And Installing For Other Types Of Gas; Substituting The Nozzle In The Main Burner; Substituting The Nozzle In The Pilot Burner - Lotus CPT-64G Guia Para La Intalación E Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CPT-64G
Burner 6 kW min. 2,75 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector
Consumption
Primary air h=mm
CPT-66G
Burner 9 kW min. 3,7 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector
Consumption
Primary air h=mm
CP-66G
Burner 13,95 kW min. 7 kW
Burner Injector 1/100 mm
Min. output adjustment 1/100 mm
Pilot Injector
Consumption

RULES FOR CONVERTING AND INSTALLING FOR OTHER TYPES OF GAS

Our appliances are tested and regulated for liquid gas (see plate inside).
The conversion or adaptation to another type of gas must be carried out by a specialised technician. The nozzles for the
various types of gas are in a bag supplied with the appliance and marked in hundredths of mm (see the "Technical Data"
table).

SUBSTITUTING THE NOZZLE IN THE MAIN BURNER

In order to operate inside the appliance, it is necessary to empty the water tub.
Remove the small knob from the panel by unscrewing it.
Remove the front fixing screws from the panel, remove the start up cable from the piezoelectric ignition device.
Using a suitable spanner, unscrew the nozzle and substitute it with the right one (see the "Technical Data" table).
The main burner does not require any regulation of the primary air.

SUBSTITUTING THE NOZZLE IN THE PILOT BURNER

The flame of the pilot burner has fixed air.
The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the
fitting and substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.

Important!

After having carried out the conversion to another type of gas, it is necessary to update the data plate, indicating the
type of gas for which the appliance has been converted.
The instructions necessary for use are enclosed with the appliance.
Check the appliances for gas leaks.
Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
Check the lighting and flame of the main burner.
We urge the user to follow the instructions when using the appliance.
GB

BURNERS TECHNICAL DATA TABLE

12,68 kWh/Kg
G30
BUTANO
30 mbar
kg/h 0,473
kg/h 0,710
kg/h 1,100

CHECKING FUNCTIONING

42
IE
12,87 kWh/Kg
G31
PROPANO
37 mbar
125
125
75
75
27
27
kg/h 0,466
15
15
150
150
85
85
27
27
kg/h 0,699
20
20
2x130
2x130
130
130
25
25
kg/h 1,084
3
9,45 kwh/m
st.
G20
METANO H
20 mbar
185
adjustable
35
m³ st./h 0,635
15
230
adjustable
35
m³ st./h 0,952
15
2x205
adjustable
41
m³st./h 1,476

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cp-66gCpt-66gCpa-66g

Tabla de contenido