Descargar Imprimir esta página

Elkay LZ Serie Manual De Instalación, Cuidado Y Uso página 24

Publicidad

Error
Error Description
Code
E001
Evaporator Thermistor Open Circuit •
E002
Evaporator Thermistor Short Circuit •
E003
E004
Condenser Thermistor Open Circuit •
E005
Condenser Thermistor Short Circuit •
E006
E007
E008
E009
E010
E011
Evaporator not cooling/Thermistor not measuring •
E012
E013
E014
E015
1000002120 (Rev. C - 01/16)
ENLZSTL8WS_1F
Enhanced EZH2O Error Codes
Evaporator Low Temperature •
Condenser Over Temperature •
Not Used
Not Used
Too Many Compressor Cycles •
Not Used
Bottle filler area obstructed •
Missing or Incompatible Filter •
Missing NFC Board •
Missing LED Board •
Corrective Action
Verify cable connector is plugged into control board (10 pin connector on
harness # 0000001225)
If error repeats, contact certified service professional
Check for excessive moisture on control board around 10 pin connector
on harness # 0000001225
If error repeats, contact certified service professional
Unplug unit for at least 30 seconds and restart
Monitor compressor for run-on condition
If error repeats, contact certified service professional
Verify cable connector is plugged into control board (10 pin connector on
harness # 0000001225)
If error repeats, contact certified service professional
Check for excessive moisture on control board around 10 pin connector
on harness # 0000001225
If error repeats, contact certified service professional
Clean condenser if needed
Check for proper fan operation (powers on, not obstructed, etc.)
Contact certified service professional
Contact certified service professional
Contact certified service professional
Clean lens on IR sensor
Unplug unit for at least 30 seconds and restart
If error repeats, replace IR sensor with 1000002434 KIT - IR SENSOR
Check that filter is installed correctly (label facing forward, white tag fac-
ing back)
Unplug unit for at least 30 seconds and restart
Replace filter
Replace filter head assembly with repair kit - 1000002030 KIT - FILTER
HEAD-BRKT-FTGS
If error repeats, contact certified service professional
Unplug unit for at least 30 seconds and restart
Verify cable connector is plugged into NFC board on filter head assembly
Verify cable connector is plugged into control board (10 pin connector on
harness # 0000001225)
Replace filter head assembly with repair kit - 1000002030 KIT - FILTER
HEAD-BRKT-FTGS
If error repeats, contact certified service professional
Verify cable connector is plugged into LED board in the bottle filler tower
assembly
Verify cable connector is fully plugged into the basin from the tower as-
sembly.
Verify cable connector is plugged into control board (18 pin connector on
harness # 1000001608)
Replace LED filter status board with repair kit - 1000002436 KIT - ALPHA
NUMERIC LED BOARD
Replace tower cable harness – 1000001609 HARNESS-BASIN FEED
TO BF
Replace fountain cable harness – 1000001608 HARNESS-CNTRL
BOARD TO BASIN FEED
Page 24

Publicidad

loading

Este manual también es adecuado para:

Ez serieEnlzstl8ws_1f