Error
Error Description
Code
E001
Evaporator Thermistor Open Circuit •
E002
Evaporator Thermistor Short Circuit •
E003
E004
Condenser Thermistor Open Circuit •
E005
Condenser Thermistor Short Circuit •
E006
E007
E008
E009
E010
E011
Evaporator not cooling/Thermistor not measuring •
E012
E013
E014
E015
1000002120 (Rev. C - 01/16)
ENLZSTL8WS_1F
Enhanced EZH2O Error Codes
Evaporator Low Temperature •
Condenser Over Temperature •
Not Used
Not Used
Too Many Compressor Cycles •
Not Used
Bottle filler area obstructed •
Missing or Incompatible Filter •
Missing NFC Board •
Missing LED Board •
Corrective Action
Verify cable connector is plugged into control board (10 pin connector on
harness # 0000001225)
•
If error repeats, contact certified service professional
Check for excessive moisture on control board around 10 pin connector
on harness # 0000001225
•
If error repeats, contact certified service professional
Unplug unit for at least 30 seconds and restart
•
Monitor compressor for run-on condition
•
If error repeats, contact certified service professional
Verify cable connector is plugged into control board (10 pin connector on
harness # 0000001225)
•
If error repeats, contact certified service professional
Check for excessive moisture on control board around 10 pin connector
on harness # 0000001225
•
If error repeats, contact certified service professional
Clean condenser if needed
•
Check for proper fan operation (powers on, not obstructed, etc.)
•
Contact certified service professional
Contact certified service professional
Contact certified service professional
Clean lens on IR sensor
•
Unplug unit for at least 30 seconds and restart
•
If error repeats, replace IR sensor with 1000002434 KIT - IR SENSOR
Check that filter is installed correctly (label facing forward, white tag fac-
ing back)
•
Unplug unit for at least 30 seconds and restart
•
Replace filter
•
Replace filter head assembly with repair kit - 1000002030 KIT - FILTER
HEAD-BRKT-FTGS
•
If error repeats, contact certified service professional
Unplug unit for at least 30 seconds and restart
•
Verify cable connector is plugged into NFC board on filter head assembly
•
Verify cable connector is plugged into control board (10 pin connector on
harness # 0000001225)
•
Replace filter head assembly with repair kit - 1000002030 KIT - FILTER
HEAD-BRKT-FTGS
•
If error repeats, contact certified service professional
Verify cable connector is plugged into LED board in the bottle filler tower
assembly
•
Verify cable connector is fully plugged into the basin from the tower as-
sembly.
•
Verify cable connector is plugged into control board (18 pin connector on
harness # 1000001608)
•
Replace LED filter status board with repair kit - 1000002436 KIT - ALPHA
NUMERIC LED BOARD
•
Replace tower cable harness – 1000001609 HARNESS-BASIN FEED
TO BF
•
Replace fountain cable harness – 1000001608 HARNESS-CNTRL
BOARD TO BASIN FEED
Page 24