Setting the lighting
duration
Turn the rotary control TIME
clockwise to increase the dura-
tion of the illumination. The
lighting duration can be adjusted
within a time window of approx.
10 seconds to 4 minutes.
Adjusting the sensi-
tivity of the sensor
Turn the rotary control SENS
clockwise to increase the
8
sensitivity of the sensor.
Note: The motion detector
responds to heat radiation. When
outdoor temperatures are low,
it is more sensitive to body heat
than when outdoor temperatures
are warm. Be sure to regulate
the sensitivity of the sensor
over the course of the year.
Setting the daylight
level
Turn the rotary control LUX
9
to increase the daylight level:
In the position, the motion
detector only reacts at night
(at approx. 10 lx). In the
position, the motion detector
also responds at daylight levels,
as long as about 20,000 lx are
not exceeded.
Aligning the motion
detector
Note: Perform this adjustment at
twilight.
Slacken the locking screw
Turn the rotary control LUX
to position
Align the motion detector
into the central region of the
desired coverage area.
Move about through the cover-
age area until you are satisfied
with the response characteristics
of the motion detector. To find
the proper orientation, change
10
.
6
10
.
7
GB/MT
37