Descargar Imprimir esta página

Wolf ICBMM15T/S Guia De Instalacion página 3

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 6
SPECIFICATIONS
Installation Requirements
A minimum 51 mm is required from the bottom of the
cooktop to combustible materials. If the cooktop is installed
above an oven, a minimum of 6 mm is required between
units. Refer to the illustration on page 6 for additional
minimum clearances.
WARNING
Failure to locate the cooktop without proper clearances
will result in a fire hazard.
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustration on
page 6. A separate circuit, servicing only this appliance is
required. A ground fault circuit interrupter (GFCI) is not rec-
ommended and may cause interruption of operation.
When multiple cooktops or modules are installed side by
side, each unit must have its own separate recommended
electrical circuit.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240 V AC, 50/60 Hz
Service
10 amp dedicated circuit
Receptacle
grounding-type (earthed)
Power Cord
Connection of this appliance should be
IMPORTANT NOTE:
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
Gas Supply
Installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code.
Locate the gas supply as shown in the illustration on the
following page.
The cooktop is equipped for use with natural or liquid pro-
pane (LP) gas. The product rating plate has information on
the type of gas that should be used. For rating plate loca-
tion, refer to the illustration below. If this information does
not agree with the type of gas available, check with the local
gas supplier.
Prior to installation, ensure that the local distribution condi-
tions (nature of the gas and gas pressure) and the adjust-
ment of the appliance are compatible. The adjustment
conditions for this appliance are stated on the label (or
1.8 m
rating plate). The data plate can be found on the underside
of the cooktop.
This appliance is not connected to a combustion prod-
ucts evacuation device. It shall be installed and connected
in accordance with current installation regulations. Par-
ticular attention shall be given to the relevant requirements
regarding ventilation.
RATING PLATE
Rating plate location.
The cooktop must be connected to a regulated gas supply.
The supply line must be equipped with an approved external
gas shut-off valve located near the cooktop in an accessible
location. Do not block access to the shut-off valve. Refer to
the illustration below.
A gas supply line of 19 mm rigid pipe must be provided to
the cooktop. If local codes permit, a certified, .9 m long,
13 mm or 19 mm ID flexible metal appliance connector is
recommended to connect the units
1
/
" NPT (or ISO 7/1-14)
2
male inlet to the gas supply line. Pipe joint compounds, suit-
able for use with natural or LP gas should be used.
The appliance and its shut-off valve must be disconnected
from the gas supply piping system during any pressure
testing of the system at test pressures in excess of 3.5 kPa.
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the system at test pressures equal to
or less than 3.5 kPa.
Wolf natural gas cooktops will function up to 3124 m in
altitude without adjustment and LP gas cooktops will func-
tion up to 2621 m. If the installation exceeds these eleva-
tions, contact your authorized Wolf dealer for a high altitude
conversion kit.
SHUT-OFF VALVE
OPEN POSITION
TO APPLIANCE
GAS SUPPLY
Gas shut-off valve.
wolfappliance.com
|
3

Publicidad

loading

Este manual también es adecuado para:

Icbmm15tf/sIcbmm15t/s/lpIcbmm15tf/s/lp