Operation
DANGER
Risk of explosion!
Do not spray flammable liquids.
ATTENTION
– Never operate device with empty fuel
tank The fuel pump will otherwise be
destroyed. This also applies to cold wa-
ter operation.
– Risk of damage! Never operate the ap-
pliance without a filter in the water con-
nection.
– Risk of damage! Do not place any ob-
jects (hose,etc.) on or over the chim-
ney.
– Device with hose drum:
Always unwind high pressure hose
completely
Safety instructions
WARNING
Long hours of using the appliance can
cause circulation problems in the hands on
account of vibrations.
It is not possible to specify a generally valid
operation time, since this depends on sev-
eral factors:
– Proneness to blood circulation deficien-
cies (cold, numb fingers).
– Low ambient temperature. Wear warm
gloves to protect hands.
– A firm grip impedes blood circulation.
– Continuous operation is worse than an
operation interrupted by pauses.
In case of regular, long-term operation of
the device and in case of repeated occur-
rence of the symptoms (e.g. cold, numb fin-
gers) please consult a physician.
Open/close the hood
Illustration
Unlock the hood lock using a screwdriv-
er, pivot the appliance hood forward
and unhook it.
Illustration
Hook in the appliance hood (see ar-
rows), pivot it up and lock in the hood
lock.
8
Operating modes
Illustration
0/OFF = Off
1 Operating with cold water
2 Operating with hot water
Turning on the Appliance
Set appliance switch to desired operat-
ing mode.
The device starts briefly and turns off, as
soon as the working pressure is reached.
Release the trigger gun.
When activating the hand spray gun the de-
vice switches back on.
Note: If no water comes out of the high
pressure nozzle, vent pump.
Vent pump:
With open hand spray gun turn device
on and off multiple times with the device
switch.
Note: By dismantling the spray lance from
the hand spray gun, the venting process is
accelerated.
Interrupting operation
Release the lever of the trigger gun; the
device will switch off.
Release again the lever of the trigger
gun; the device will switch on again.
Select spray type
Close the hand spray gun.
Use the safety catch to secure the
handgun lever.
Turn the casing of the nozzle till the de-
sired symbol matches the marking.
High pressure circular spray
(0°) for specially stubborn dirt
Flat low pressure spray
(CHEM) for operating using de-
tergents or cleaning at low
pressure.
High pressure flat spray (25°)
for large dirt areas
– 5
EN