4.14. Never fix the gas outlet flex in a chimney or a flex already installed which diameter is 4 times as large as the
stove's flex (Ø80 max. 200cm
the gas outlet must be channeled to the top.
If the tube that was installed previously was used with another type of heating (wood, oil, etc.), you MUST
clean it thoroughly, to reduce the risk of fire in the gas vent.
4.15. Gas outlet flex cannot be installed in a share pipe such as the pipe of an extractor hood, another stove or
heating system.
4.16. If gas outlet installation is wrong, combustion air's homogeneity might be bad which could make the wall of
the house or the building dirty, aggregate trash inside the stove and thus be the source of premature
degradation of the spare parts and gas outlet pipe.
4.17. The air input pipe should not be drained with the risk of affecting the correct operation of the stove. For this
reason, and in order to facilitate fresh air input, it is necessary to set up a ventilation grid AT NOT LESS than
50cm both horizontally and vertically from gas output, see point 4.11.
Direct air currents shall also be avoided as they might prevent a correct operation of the stove and as a
consequence, heat performance.
4.18. In any case the design of the chimney termination will impede the free diffusion in the atmosphere of
combustion products. A metallic mesh with a gap of 3x3 cm can be placed to avoid the entry of birds or
unwanted objects.
COMPLIANCE WITH THESE NORMS ARE OUT OF ECOFOREST'S CONTROL; ECOFOREST DOES NOT BEAR THE
RESPONSIBILITY FOR ANY RESULTING DAMAGE.
WE RECOMMEND THAT A CONFIRMED SPECIALIST SETS UP YOUR PELLETS STOVE.
4.19. Check the space between the stove, the fuel, and any flammable material, check drawing 5 and 6.
4.20. Do not install the stove in a sleeping room.
4.21. The power cable provided by ECOFOREST is 1.4m long; you might need a longer one. Always use a cable with
ground plug.
FREE SPACES FREE SPACES AND MINIMUM DISTANCES WITH FLAMMABLE MATERIAL.
Security distances should be respected when the stove is installed in spaces where materials, either
construction materials or those surrounding the stove, are likely to be flammable.
4.22. If the floor is made of a combustible material, install a fire protection between the floor and the stove.
A
Lateral wall.
Back of the stove. Minimum separation
B
that
allows
visualizing
marking the stove.
C
1,5 x depth of stove.
D
Shelf.
E
Depth of stove.
2
with flex of Ø100 max. 314 cm
LOCATION AND SAFETY DISTANCES.
≥ E
the
label
≥ 80 mm
See dimensions
≥ 600 mm
See dimensions
30
2
). When installing the stove in higher section
Drawing 5