It consists in controlling the combustion air inlet and gas outlet; make sure nothing prevents normal
circulation (e.g. bird nests). The gas outlet must also be inspected for possible water infiltrations.
In addition, it is recommended to clean the base of floor of the stove, the back side of the stove that you
reach through the back grid or lateral doors, in order to take eventual dust away that might have stacked during
summer time.
6.
PROBLEMS AND RECOMMENDATIONS.
6.1.
Do not turn the stove on and off successively because this might damage the electronical components and
motors ~230/240V - 50Hz.
6.2.
Do not touch the stove while your hands are wet. Though the stove is equipped with ground plug, it remains
an electric machine that could cause electric discharge if handled incorrectly. A qualified technician only shall
resolve the eventual problems.
6.3.
Do not remove any screw of the zones exposed to high temperature before they have been lubricated
properly with lubrication oil.
THE STOVE REMAINS OUT OF POWER:
6.4.
Make sure the stove is connected and the plug is leading power.
6.5.
Make sure the cable is not damage or cut.
While the stove is disconnected, dismantle the right door of the stove and check if any lead of the C.P.U. is
slack.
6.6.
Check the C.P.U pilot. If it is OFF, check also the fuse on the C.P.U.
PELLETS DO NOT FALL AND THE STOVE DOES NOT TURN ON:
6.7.
Check if there are pellets in the hopper.
6.8.
Make sure the glass door is closed.
6.9.
Make sure the gas outlet tube is not obstructed by anything (e.g. bird nest, plastic, etc.).
6.10. Make sure the exhaust motor works, because if it does not work fuel will not fall.
6.11. If the reducer motor does not rotate and the displays indicates the pulses, the first thing to do will be unplug
the stove and verify if the safety thermostat has been activated. With the stove unplugged, check that the
safety thermostat is located inside the stove. We will find the safety thermostats (with and without reset) in
the stove models by accessing them through the right-hand side (opening the door to the right). One of the
thermostats is located on the upper part of the housing and the other one in the lower part of the hopper.
Insert stoves have the hopper thermostat in the same place, but the safety thermostat may be activated
from the outer side simply by unscrewing the topper that protects it. In model ECO III insert (drawing 30), the
user may find the safety thermostat at the bottom of the right panel. However, the safety thermostat on the
Córdoba stove can be reached by opening the housing door, above the door closure mechanism.
To activate it, you must press the button. If the thermostat is activated you will hear a "click". If the safety
thermostat had been activated before, get in touch with your distributor.
CHECKING AT BEGINNING OF SEASON.
WHAT NOT TO DO.
WHAT DO TO IF...
41