MixRite operates in the following conditions:
From a minimum flow rate of 20 L/H (5.3 Gal/H) and up to 2,500
L/H (660 Gal/H)
Temperature not lower than 4°C (39°F) and not higher than
40°C (104°F)
Water pressure between 0.2 Bar to 8 Bar (2.9 to 120 PSI)
The additive may be added to the water flow according to the
required dosing percentage:
0.1% to .9% in models: 569(CL/CW/PVDF)
0.3% to 2% in models:
576IN, 577IN.
0.4% to 4% in models:
578IN, 579IN.
3 % to 10% in models: 574(CL/CW), 575(CL/CW)
Fixed dosage 0.8 % in models: 571 Green, 568AG
Water pressure loss:
Pressure loss in the lower flow rates 0.1 Bar and in the higher flow
rates up to 1 Bar.
Models with 0.3%-2%: from 0.1 Bar up to 1 Bar in proportion to
the water flow
Models with 0.4%-4%: from 0.2 Bar up to 1.2 Bar in proportion to
the water flow
Models with 3%-10%: from 0.5 Bar up to 1.8 Bar in proportion to
the water flow
The MixRite inlet and outlet are ¾" BSPT male thread.
The additive tank should be placed beneath the MixRite.
Mounting the MixRite
1. Prepare the MixRite site.
The MixRite intake and outlet must
reach the intake and outlet pipes.
The MixRite must be positioned above
the liquid additives container.
2. Screw the MixRite bracket onto a wall or
any stable vertical base.
3. Press the MixRite onto the bracket.
The nipples on the MixRite must click
into the holes in the side of bracket.
I-870
Rev G - 37915
Technical Data
570(CW/CL/PVDF), 571(CW/CL/PVDF),
572(CW/CL/PVDF), 573(CW/CL/PVDF),
www.ghlinc.com
Page 3 of 36