UV STERILIZER/
CLARIFIER
Examples of different installations
Exemples d'installations
Beispiele für verschiedene Installationen
Ejemplos de diferentes instalaciones
UV STERILIZER/
CLARIFIER
UV STERILIZER/
CLARIFIER
1
EXTERNAL FILTER
POWERJET
PUMP
EXTERNAL FILTER
MAX-FLO
PUMP
POWERFLO
UNDERWATER
FILTER
POWERJET
PUMP
ENGLISH
POWERCLEAR MAX UV STERILIZER/CLARIFIER
For pond use only
Read thoroughly prior to installation and operation

IMPORTANT SAFETY INSTRUCTIONS

DANGER
1.
- To avoid possible electric shock, special care should be taken since
water is employed in the use of pond equipment. To guard against injury, basic
READ AND FOLLOW ALL SAFETY
safety precautions should be observed.
INSTRUCTIONS
and all the important notices before using this appliance.
2. For each of the following situations, do not attempt repairs yourself; return the
appliance to an authorized Laguna dealer for service or discard the appliance.
A. Do not immerse the product in water! If the product drops into water, don't
reach for it; first disconnect the item from the power supply and only after
that take the item out of the water. Carefully check the product after
installation; if any electrical parts are wet, disconnect the cord from the
power supply.
B. External flexible cord is not replaceable. The transformer should be disposed
if the cord is damaged. Do not operate any appliance which malfunctions,
has a damaged cord or has been dropped or damaged in any way.
Never cut the cord.
C. If the appliances electrical connections gets wet, do not touch anything.
Disconnect the power supply before performing any necessary maintenance.
3. Children must be closely supervised at all times near water.
IMPORTANT:
4.
Always disconnect the appliance when not in use, before adding
or removing parts and before cleaning. Never yank the cord and never lift the
appliance by the cable.
NEVER LOOK AT A UV LAMP WHEN SWITCHED ON. IT CAN
5.
SEVERELY DAMAGE YOUR EYESIGHT.
6. THIS IS A UV STERILIZER/CLARIFIER FOR PONDS. Do not use the appliance for any
purpose other than that for which it is intended.
• Do not use this appliance in swimming pools or other situations where people
are immersed.
• This product is designed to work with water not exceeding a temperature of
35ºC (95ºF).
• Do not use this product with liquids other than water.
7. Do not expose the product to temperature close to 0ºC (32ºF) or below. In
winter, place the product in a dry and protected place.
IMPORTANT:
8.
Electrical connection must be in accordance with data on the
rating label; the appliance can be operated only after having been correctly
installed. The electrical safety is guaranteed only when the item is connected to
an earthed/grounded circuit.
9. It is best not to use an extension cord. If an extension cord is necessary, check to
be sure the connection is waterproof and the extension cord is at least
equivalent (for thickness, insulation and number of wires) to the cord of the appli-
ance. If in doubt, consult a qualified electrician.
10. Never use the product without water.
IMPORTANT:
11.
The power supply should pass through a Residual Current
Device (RCD) or Ground Fault Circuit Interrupter (GFCI) with rated residual
operating current not exceeding 30mA.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
12.
ELECTRICAL INSTALLATION
Place the appliance in a fixed position, in a dry and protected place with sufficient
ventilation around it.
• Protect the appliance from direct sunlight.
• Be sure that there is enough room around it for maintenance operations.
• To avoid overheating, do not cover the appliance.
WARNING - THIS APPLIANCE MUST BE EARTHED/GROUNDED.
IMPORTANT:
The maximum operating pressure is 0.1 MPa (1 bar).
FOR POND USE ONLY.
ADDITIONAL INSTRUCTIONS FOR U.K. ONLY
UV Sterilizers - Low Voltage Transformers without plug
This product is designed to be permanently wired to the mains supply in a dry weather-
proof enclosure through a double pole switched fused spur which complies to BS3676,
fitted with a 3 Amp fuse. The installation must conform to the regulations of the Local
Electricity Authority which could include the use of plastic or metal conduit to protect the
cable. A 30 mA Residual Current Device 'RCD' must be fitted to the mains supply.
WARNING - THIS APPLIANCE MUST BE EARTHED.
IMPORTANT - The wires in this mains lead are coloured in accordance with the
following code:
BROWN - LIVE
BLUE - NEUTRAL
GREEN/YELLOW - EARTH
The Brown lead should be connected to the Live terminal, which may be marked
with an 'L' or coloured brown or red.
The Blue lead should be connected to the Neutral terminal, which may be marked
with an 'N' or coloured blue or black.
The Green/Yellow lead should be connected to the Earth terminal, which may be
marked with an 'E' or coloured green or yellow.
MAINTENANCE
WARNING: Always stop the water supply and unplug or disconnect
all appliances in the pond from the electricity supply while the
equipment is being installed, repaired, maintained or handled. Never
yank the cord and never lift the appliance by the cable.
It is recommended that you:
• Do not pull the internal wires.
• Make sure that internal parts of the appliance are dry before, during and after the
maintenance operations.
• Check that all the components are present and have been reassembled in the
correct way; if in doubt consult your local dealer for a replacement of the
defective component.
• Check that there are no leaks inside the appliance before connecting it to the
electricity supply after maintenance.
TRANSFORMER INSTALLATION
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE TRANSFORMER
IMPORTANT:
The UV Sterilizer/Clarifier is designed to function in tandem with
the pond pump. Therefore, always unplug the UV Sterilizer/Clarifier when the pump
is unplugged or stops functioning.
Do not place it close to flammable materials.
Do not expose to rain.
To avoid overheating, do not cover the transformer.
Electrical connection must be in accordance with data on the rating label.
The cord should be protected from abrasion, cuts and any other damage. If the cord
is damaged, discard the appliance. The socket must be positioned in a dry and
protected place.
This appliance is made to work at normal environment temperatures; never use it
for any other purpose than that which is intended.
UV STERILIZER/CLARIFIER INSTALLATION
WARNING: Do not install the UV Sterilizer/Clarifier in the pond.
Do not immerse in water.
Check that the installation is done correctly before switching on the appliance. The
connection has to be made in accordance with the regulations. Carefully check that
the electrical cords are properly connected. If in doubt, consult a qualified electrician.
• To comply with electrical safety, the UV Sterilizer/Clarifier cord is supplied with
a plug that cannot be replaced.
• The cord should be protected from abrasion, cuts and any other damage.
• Do not use the UV Sterilizer/Clarifier for any other purpose than that which it is
intended for.
• Do not use this appliance in swimming pools or other situations where people
are immersed.
CONNECTING THE UV STERILIZER/CLARIFIER TO
THE TRANSFORMER
CAUTION: The transformer should be plugged into a Residual
Current Device (RCD) or Ground Fault Circuit Interrupter (GFCI).
CAUTION: Only assemble cables into connectors with power OFF.
1. CONNECTING THE UV CABLE TO THE TRANSFORMER
The UV unit comes with a weatherproof plug with a seal cap. Connect the plug to the
transformer socket. Push firmly to make a secure connection, then screw on the seal cap.
2. MOUNTING THE TRANSFORMER
When planning where to install the transformer, make sure
that the cable is long enough to stretch from the electrical
socket, into which you will plug your transformer, to the
point where you will install the transformer. The trans-
former has four holes for mounting screws (not included).
Place the transformer in the desired position and mark the
four screws holes. If mounting on a wooden surface, screw
in the appropriate screws. If mounting on a concrete sur-
face, use appropriate anchors and screws for a secure
installation.
DO NOT USE EXTENSION CORDS!
Mount the transformer beyond the reach of small children and at least 1 m (3 ft)
above the floor.
2