AUX ALMD-NHA Serie Manual De Instalación Y Usuario página 75

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Models 48 / 60 (3 phases):
Indoor unit
Note:
- The connection wire of indoor units should be connected to the corresponding terminals board: otherwise it will cause
the unit failure or even damage the units.
- Connect the grounded wire correctly, otherwise will cause the malfunction of some electrical component and shock
or fire indeed.
- Don't reverse the power polarity.
- Must fix the screw nail of the firmly wire, then drag the wire lightly, confirmation whether it's firmly.
Wiring diagram of indoor unit:
WIFI MODULE
QRD-WIFI-SYE1
(Optional CL93565)
12V
TIMER
FAN
SWING
MODE
GND
FUNCTION
ON/OF
A
WIRED CONTROLLER
XK-05
B
(Supplied CL93920)
NOTE: The connection on the side of the wall
control can be through an aerial connector.
Operation of remote ON/OFF:
The operation is as follows:
1) With the unit running if the contact opens unit stops and remote control is locked.
2) With the unit stoped if the contact opens unit will continue stop and remote control is locked.
NOTE: To use this function this function you have to set the parameter "0901" see next page.
CN3
X1 (red)
X2 (black)
CN4
X3 (green)
X4 (yellow)
4 wires
(50mts max.)
Outdoor unit
MAIN PCB
485-BUS1 (2)
A
B
The terminals that are between dashed
Outdoor unit
lines is optional its use
interconnection
75
Remote ON/OFF
ID1
L
220-240V, 50Hz, 1-
N
L
L
N
220-240V, 50Hz, 1N-

Publicidad

Tabla de contenido
loading

Tabla de contenido