AUX ALMD-NHA Serie Manual De Instalación Y Usuario página 93

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

"Shielding" function display
When unit is locked by centralized control, the wired controller will display
"Mute" function display
When the unit enter silent function, display "
cancelled,the icon does not display.
Note: The unit without silent function can also set silent through wired controller, but it
shows in the way of low wind grade, but
"Oil Return / Defrost" function display
When the unit is running in the state of Oil Return or Defrost,
lighting on wire controller.
When the unit has finished Oil Return or Defrost process,
"Filter Screen Clean"function display
Filter screen cleaning reminder function: The unit can record its running time, when
reaching the time set by the user, it will remind the user to clean the filter screen, so
as to avoid prolonged cleaning and filter screen blockage, which can result in poor
heating/cooling effect, abnormal protection, bacterial breeding, and other problems.
When the running time reaches the filter screen cleaning reminder time set by a user,
the unit will give out a reminder of filter screen cleaning, wired controller displays"
icon, reminding the user to clean filter screen. At this moment, long press "Timer"
button for 5S to cancel the reminder, then the icon does not display. A filter screen
cleaning reset signal is sent to the unit.
Celsius and Fahrenheit switching display
When users set Celsius to be valid, the wired controller will display Celsius temperature.
When users set Fahrenheit to be valid, the wired controller will display corresponding
Fahrenheit temperature synchronously.
"Child Lock" function display
Press both "
" and "
display "
" . In the state of locking, operations on the wired controller are disabled
(but remote control receiving is valid).The method of unlocking: Press both "
"
" buttons for more than 5S or power off the unit to release the locking
("
" does not display).
Remote control function
The wired controller can receive remote control commands and update the current
status.
Start-up the unit with remote controller, wired controller work in accordance with the
state set on the remote controller and displays corresponding working mode;
Room temperature sensorequipped on the wired controller
When the wire controller is equipped with a room temperature sensor and the sensor
is not damaged, it is default that the ambient temperature detected by the sensoron
the controller and the temperature value will be sent to the main PCB of the unit.
If the wire controller is not equipped with a room temperature sensor or the sensor is
damaged, the room temperature will be detected by the temperature sensor of the
unit itself.
Note: to do the setting, please see next page.
Fault display
When the unit has fault, the time bar will directly display the fault code and flash, the
display mode is Er: MM (MM is the fault code, please read the corresponding
product manual).
" buttons for more than 5S to enter locking, the controller will
93
" icon, when silent function is
"
" does not display.
"
"
icon is
"
"
icon does not display.
"
".
"
" and