Descargar Imprimir esta página

Display Controller Operation; The Buttons Of Led Wire Controller; Turn On/Off The Heat Pump; Set The Water Temperature - GRE HPM Serie Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35

6. Display controller operation

6.1 The buttons of LED wire controller

When the heat pump is running, the LED display shows the water inlet temperature.
LED 1 is on when compressor is running.
LED 2 is on if the unit is in fault.

6.2 Turn on/off the heat pump

Press
to turn on the heat pump, the LED display shows the water setting temperature for 5s, then show
water inlettemperature.
Press
again to turn off the heat pump.

6.3 Set the water temperature

Press
or
directly to adjust water temperature (range:.10—42℃)
Press
to save the setting thenexit.
NOTE: the heat pump can run only if the water circle/filtration system is running.

6.4 Parameter checking

Press
,it will enter the parameter checking, Press
again, it will show the measured value.Lastly press
Code Parameter
d0
Ambient temperature
d1
Water temperature
Notice: It can't set the Parameter data by end-users.
or
to choose the code d0/d1,press
to exit.
26

Hide quick links:

Publicidad

loading

Este manual también es adecuado para:

Hpm20Hpm30Hpm40712457125871606