Connecting the pressure side/suction side
E
• Only remove the protective cap just before you connect the pipe or hand guard.
• The position of the pump outlet can be changed. The pump casing can be turned to
achieve a different position.(→ Turning the pump casing to achieve a different po-
sition )
Turning the pump casing to achieve a different position
If necessary, the pump casing can be turned to change the position of the pump out-
let by 90°.
• The pump casing can only be mounted in the two positions indicated.
• Reassemble the pump in the reverse order.
– Tightening torque for all loosened screws: 3 Nm
28