AUXILIARY
PROGRAM PUMP SETTINGS
3. Calculate the Pump Speed Percentage.
Metering Pump Output Requirement (gpd) x 100
Metering Pump Maximum Output (gpd)
4. Program the Pump Operating Mode and the Pump Speed Percentage.
Unlock the Keypad
Press
and
MODE
Pump Operating Mode
First, press and continue to hold
modes of operation. When the display shows AUXILIARY, release both buttons to select.
The operating mode is now set.
Pump Speed Percentage
The pump speed can be programmed from 10% to 100% in 1% increments. First, press
and continue to hold
determined in #3. When the display shows the desired percent, release both buttons to
select. The percentage is now set.
(12-24 VAC/VDC signal)
%
simultaneously and hold for 5 seconds to unlock the keypad.
MODE
%
, then press
AUXILIARY
+ +
KEYPAD LOCKED
Example of control panel with keypad locked.
AUXILIARY
Example of control panel with the pump speed set for 20%.
USA and Canada 800.683.2378, International 904.641.1666
= Pump Speed Percentage
, then press
or
or
to adjust the speed percentage
20%
+ +
20%
continued
to scroll through the
Econ FP
17