OUTPUTS
Item Number
Pump
Prefix
Tube
E20PHF
F
E20PHG
G
E20PHH
H
Item Number
Pump
Prefix
Tube
E20PHF
F
E20PHG
G
E20PHH
H
NOTE: Injection check valve included.
NOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on
pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
8
Econ FP
Roller
Turndown
Assembly
Ratio
White
10:1
Black
10:1
Black
10:1
Roller
Turndown
Assembly
Ratio
White
10:1
Black
10:1
Black
10:1
www.stenner.com
Gallons
Gallons
per Day
per Hour
4.5
0.19
16.0
0.67
30.0
1.25
Approximate Maximum Outputs @ 50/60Hz
Liters
Liters
per Day
per Hour
17.01
0.71
60.48
2.52
113.40
4.72
Approximate Maximum Outputs @ 50/60Hz
Ounces
Ounces
per Hour
per Minute
24.0
0.40
85.3
1.42
160.0
2.67
Milliliters
Milliliters
per Hour
per Minute
708.8
11.8
2520.0
42.0
4725.0
78.8
Pressure
psi
80
80
80
Pressure
bar
5.5
5.5
5.5