Electrical Connections
WARNING :Field wiring connections and electri cal grounding must comply with local codes,
or in the absence of local codes, with the la test edition of the National Electrical Code,ANSI/
NFPA 70, or in Canada, Canadi an Electrical Code, CSA C22.1Part1.

Electrical Connection

POWER CORD:

• The electric power supply requirement for
this water heater is 120 VAC/60HZ, 2 Amps.
• The water heater comes with a three (3) pin
power supply cord. Use only a power outlet
with a ground terminal.
• The installation of an electric leakage
breaker is recommended. (GFCI)
• Keep any excess of the power supply cord
on the outside of the water heater.
• If local codes require hardwiring, see
instructions for "Hardwiring the Electrical
Connections".
WARNING: Shock hazard line voltage is
present. Before servicing the water heater, turn
off the electrical power to the water heater at
the main disconnect or circuit breaker. Failure to
do so could result in severe personal injury or
death.

Electric Wiring Diagram

PLEASE NOTE: EL22 IS FOR OUTDOOR PERMANENT INSTALLATIONS ONLY AND EL22-I IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL
AND ALL ECCOTEMP CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.ECCOTEMP.COM/SUPPORT FOR MORE INFORMATION.
Support: Eccotemp.com/help-desk
HARDWIRING THE ELE CTRICAL
CONNECTIONS:
• Wiring should be carried out by a qualified
• The water heater requires 120 VAC/60Hz
• DO NOT connect grounding wire to water
• An ON/OFF switch must be provided and
• Wire the water heater exactly as shown
inside
• A green screw is provided in the junction
• Connect the live wire to black leg wire and
disconnection when servicing controls. Wiring
errors can cause improper and dangerous
operation. Verify correct operation after
servicing.
Shop Online: Eccotemp.com/products
electrician in accordance with local codes.
and should be properly grounded.
pipes, gas pipes, telephone cables,
lightning conductor circuits and to
grounding circuit of other equipment that
carry a ground-fault interrupter.
installed for the incoming 120VAC power.
below. A wiring diagram is also found
of the cover panel.
box for grounding connection.
the neutral wire to the white neutral wire.
CAUTION: Label all wires prior to
Store Locator: Eccotemp.com/locator
EL22
16