APPLIANCE STORAGE FOR EXTENDED
PERIODS OF TIME
If the appliance is not used for an extended period of
time:
● Turn off the appliance and unplug the power cord (13)
from the wall outlet.
● After one day after turning the appliance off, empty
the water tank (5).
Troubleshooting
WARNING AND ERROR CODES
The occurrence of some issues during operation is indicated on the appliance display.
Warning codes
Warning code
P1
P2
Error codes
Error code
AS
E3
ES
EC
Indicator name
Automatic defrost function is enabled.
The water tank is full or incorrectly installed.
Error name
Humidity sensor error.
System error.
Temperature sensor error.
Leakage of coolant.
● Clean the housing of the dehumidifier (2), the air
inlet (7) and outlet (3) grille, and the air filter (10).
● Wind the power cord (13) and secure it to the
appliance using the bracket (14).
● Put the appliance in a plastic bag.
● Keep the dehumidifier in a vertical position, in a dry
and well-ventilated place.
Solution
Do not turn off the appliance – let the
defrosting process continue until the end.
Empty the water tank or install it properly.
Solution
Disconnect the appliance from the power
outlet. Then reconnect it to the power
outlet. If the problem persists, contact
a professional service centre.
Contact a professional service centre.