EASY TO MOVE WITH YOU
One of the great advantages of this device is
that it can be carried anywhere, thanks to the
carrier handle (H) or the shoulder strap (13).
Some HOT water may leak out of the
accessories during active use, especially when
the tank has just been filled, while carrying out
the cleaning operations and as a consequence
of movement of the device.
POWER CORD-WINDER
When putting Vaporetto away, it is possible to
wind the power cord underneath it. To wind the
power cord, turn the black pin on the front of the
bottom part of the device and wind the power
cord as shown in picture.
PROBLEM
ON lamp (C) does not come on
when first starting
ON lamp (C) on but no steam
is delivered
The safety cap cannot be
unscrewed
VAPORETTO HANDY
• Before
operation, make sure to always disconnect
the appliance from the electrical outlet.
• We recommend that the bristles of the brushes
are allowed to cool down in their normal
position after use, so as to avoid any mis-
shaping.
• To clean the body of the appliance, simply use
a moist cloth.
Regularly check the status of the red gasket lo-
cated in the moulded plug (3). If necessary, re-
place it with the appropriate spare part (14) as
below .
- Remove the broken / damaged red gasket.
- Insert the new one. Put it on the steam nozzle
- Lubricate the gasket with some vegetable oil.
TROUBLESHOOTING
Check that the plug is correctly plugged into a suitable current socket.
Ensure that the appliance has been turned on using the ON/OFF switch
(B).
Wait for the Steam pressure indicator lamp (D) to turn off (approx. 5
minutes). If the lamp (D) is off and steam is still not delivered, there is no
water in the boiler. Fill according to the instructions given in the manual.
Ensure the machine is off and disconnected from the electrical outlet
and enable the steam control lever (4) on the steam gun (2) until the
steam flow ceases (paragraph "SAFETY CAP / SHORTAGE OF
WATER")
If the problem persists, unscrew the cap at the same
time as applying gentle pressure with fingers to the cap
pin (see fig. A)
13
CARE OF YOUR APPLIANCE
attempting
and push it until it rests in the groove.
SOLUTION
any
maintenance
Fig. A