In order to carry out maintenance, repairs or cleaning, first
disconnect the unit from the compressed air network, after
having correctly carried out the DEPRESSURISATION
procedure described in Section 9 of the Manual.
Never point the unit towards yourself, other personnel or
animals.The thinners and dilution media used can cause
serious injury. With this unit the product is sprayed at a very
high pressure. The stream coming from the gun, from leaks,
or due to the breakage of a component in the unit, could cause
the product to be injected at high pressure under the skin.
LIkewise if the product is sprayed or splashed in the eyes it
can cause serious harm.
Never attempt to stop the application stream or a leak with
your hand or any other part of your body. If you suspect you
may have sprayed the product on your skin, IMMEDIATELY
SEEK MEDICAL ATTENTION. This incidence must not be
treated as a simple cut. Describe the product with which it
ocurred to the Doctor in as much detail as possible.
The location where work is carried out must have sufficient
ventilation in accordance with current legislation and regulations.
Near the unit, only keep the amount of product and thinner
required for the work being done at that time. After work has
been completed, thinners and the product to be applied must
be returned to their corresponding storage location.
Keep the working area clean and free of potentially dangerous
waste (thinners, rags, etc.) While work is in progress, there
must not be any source of ignition (naked flames, lighted
cigarettes, etc.) in the working area as these might generate
easily flammable gases. Likewise, the approved protective
means must be used (breathing, hearing, etc.) in accordance
with the regulations established in this regard.
If the unit is used in an inadequate manner or its components
are altered in any way, severe material damage may occur
and bodily harm may be caused to the operator, other
personnel and/or animals and may even cause death.
SAGOLA, S.A. accepts no responsibility in for any damage
caused through the incorrect use of the unit.
Always use approved breathing units in accordance with current
standards and regulations in order to protect yourself from
emissions produced during application.
Never exceed the maximum operation pressure.
By following the instructions set out in this manual you will
ensure good spraying and quality of finish.
This device has been manufactured with great precision and
has been subjected to a large number of controls before
leaving the factory.
The WARRANTY is valid for three years, counted as of the
date of purchase, which will be indicated by the seller in the
place provided for this purpose, together with his stamp.
Once the unit has been received, please complete the
warranty and send this to the manufacturer for validation.
This WARRANTY covers any manufacturing defect, which
will be repaired free of charge. However, any malfunction
resulting from he incorrect use of the unit, such as inadequate
connections, breakage due to dropping, or similar, the normal
wear of components and in general any deficiency not
attributable to the manufacturer of the device, are expressly
excluded. Likewise, the WARRANTY shall be rendered null
and void when it is evident that the unit has been handled
by persons other than our Technical Assistance Service.

15. HEALTH AND SAFETY

16. OBSERVATIONS

17. WARRANTY CONDITIONS

- 24 -
As a general preventive measure we advise you to wear
goggles in accordance with the specific environmental
regulations and characteristics for the work centre.
Use gloves when handling the product (see the manufacturer's
recommendations) and cleaning the gun.
If, when the gun is in use, the ambient noise level exceeds
90 dB. the use of approved hearing protection is
recommended. The gun in itself does not propitiate any
mechanical risk of perforations, impact or pinching, except
those deriving from incorrect installations and handling.
USE SAGOLA ANTISTATIC HOSES TO ELIMINATE
POSSIBLE ELECTRICAL DISCHARGES THAT MIGHT
CREATE THE RISK OF FIRE OR EXPLOSION.
Pay adequate attention when handling the unit in order to
prevent any damage that might lead to dangerous situations
for the user or personnel standing near the unit, as a
consequence of leaks, breakages, etc.
The equipment has been designed for use at ambient
temperature. The maximum operating temperature is 50ºC.
The use of solvents and/or detergents that contain halogenated
hydrocarbons (trichloroethane, methyl chloride, etc.), may
cause chemical reactions in the unit as well as in its zinc-coated
components (trichloroethane mixed with small amounts of
water produces hydrochloric acid). For this reason, these
components may rust and in extreme cases the chemical
reaction caused may be explosive. We recommend you use
products that do not contain the aforementioned components.
Do not use acids, soda (alkalis or pickling substances, etc.)
for cleaning under any circumstances.
In general, precautions must be taken whenever the unit is
handled, in order to prevent any deterioration to it.
Connectors must be securely tightened and in good condition.
Safety standards must be understood and applied.
Any non-compliance with the indications set out in this manual
may lead to incidents affecting the physical integrity of the
user or other personnel or animals.
Respect and comply with indications relating to the
conservation of the environment.
Should you have any doubts, please contact SAGOLA S.A.
Customer Service.
This WARRANTY does not support any undertaking made
by anyone outside our Technical Service.
In the case of any breakdown during the guarantee period,
please attach the completed warranty certificate to the unit
and deliver this to the nearest Technical Assistance Service
or get in touch with the factory.
Any demand of greater importance against the supplier, in
particular compensation for damages, is excluded. This is
also applicable to any damages that might arise during
counselling, while acquiring practice and during demonstration.
Consequently, the services rendered under guarantee do
not involve an extension of the warranty period.
Any device for which there is no duly completed guarantee
certificate in the files of SAGOLA S.A. will be rejected.
The manufacturer reserves the right to make technical
modifications.