Attaching The Flue Duct - Bosch HCP50652UC Manual De Instalación

Ocultar thumbs Ver también para HCP50652UC:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7. Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (E) in terminal box
using UL listed wire connectors.
A
A Installation pipe
B Cable connector listed in UL
C Black wires
8. Tighten strain relief screw.
9. Install the junction box cover.
10. Plug the cable connector located on the top of the
junction box.
Attaching flue duct
Hidden surfaces may have sharp edges. Use caution
when reaching behind or under appliance.
1. Remove the protective foil from both flue ducts.
2. Push one flue duct into the other.
Notes
To prevent scratches, lay paper over the edges of
the lower flue duct to protect the surface.
For ducted operation, turn the upper flue duct so
that the ventilation slots point downward.
E
C
D
B
D White wires
E Yellow-green ground wire
3. Remove the protective foil from the extractor hood.
4. Place flue ducts on the appliance.
5. Push the inner flue duct upwards and attach it to the
angle brackets on the left and right.
6. Screw the flue duct to the sides of the angle bracket
using two screws.
A
7. Fasten the lower part of the flue duct using two
screws.
8. Remove the protective paper from the lower flue duct.
9. Install metal-mesh grease filter.
Removing the appliance
1. Remove the metal-mesh grease filter.
2. Loosen the flue duct.
3. Disconnect the appliance from the power supply.
4. Loosen the exhaust air lines.
5. Loosen screws for fastening the appliance.
6. Remove the appliance.
B
Page 11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hcp56652uc

Tabla de contenido