Appendix 1: Technical data
Model
Nominal output
Flue connection (diameter)
Weight
Recommended fuel
Fuel property, max. length
Mass flow of flue gasses
Flue gas temperature measured in the measurement section
Temperature measured at appliance exit
Minimum draught
CO emission (13%O
)
2
NOx emission (13% O
2
CnHm emission (13%O
Particulate emission
Particulate emission in accordance with NS3058-NS3059
Efficiency
18
)
)
2
Subject to change because of technical improvements
ZEN
4.75 kW
150 mm
100 -115 kg
Wood
30 cm
5.1 g/s
198 °C
247 ℃
12 Pa
0.09 %
111 mg/Nm³
238 mg/Nm³
293 mg/Nm³
4.76 g/kg
80.1 %