Alarm
Cause
Boiler level alarms
AL10
The alarm is enabled if the level
probe is open continuously for
Self-level
more than the time set on the
alarm
"timeout level" menu parameter
Alarms related to brewing timeout
AL11
The alarm is enabled if the
Brewing
continuous coffee supply remains
active for more than 2 minutes
timeout
Alarm related to the lack of water in the jug
AL12
The alarm is enabled with the
jug level sensor open (therefore
Empty jug
the water in the jug has dropped
under a certain level
Effect
The boiler loading and boiler heating
functions are disabled.
The alarm is reset by pressing the enco-
der and the machine resumes loading
The brewing stops and the Led of the
selected dose start flashing.
The alarm is reset by pressing the encoder
All the Leds in series start flashing [Led
2, Led 3, Led 4] and all the functions of
the machine are blocked (heating, boiler
load, brewing, etc.). If it happens du-
ring brewing, the brewing in progress is
blocked. The alarm is canceled once the
jug is filled, the Leds stop flashing and all
the functions are restored as a POWER ON
| 85