Induction System

QR-25 Series
52201-107, December 2012
Excessive compressor RPM's (speed) could cause a pulley or sheave
to shatter. In an instant, the pulley or sheave could separate into
fragments capable of penetrating the belt guard and causing
bodily harm or death. Do not operate the compressor above the
recommended RPM (refer to SECTION 2, Specifications).
Guards
All mechanical action or motion is hazardous in varying degrees and needs
to be guarded. Guards should be designed to achieve the required degree of
protection and still allow full air flow from the compressor sheave across the
unit. Guards shall be in compliance with OSHA safety and health standards
29 CFR 1910.219 in OSHA manual 2206 and any state or local codes.
Guards must be fastened in place before starting the compressor
and never removed before cutting off and locking out the main
power supply.
Check Valves
Check valves are designed to prevent back-flow of air pressure in the compressed
air system (air flows freely in one direction only). The check valve must be
properly sized for air flow and tempera ture. Do not rely upon a check valve
to isolate a compressor from a pressurized tank or compressed air
delivery system during main tenance procedures!
Manual Shutoff Valves
Manual shutoff valves block the flow of air pressure in either direction. This
type of valve can be used to isolate a compressor from a pressurized system,
provided the system is equipped with a pressure relief valve ca pable of being
manually released. The pressure relief valve should be installed between the
manual shutoff valve and the compressor (refer to Fig. 3-2, Typical Drop
Leg & Component Location).
Pressure Relief Valves
Pressure relief valves aid in preventing system failures by relieving system
pressure when compressed air reaches a determined level. They are available
in various pressure settings to accommodate a range of applications. Pressure
relief valves are preset by the manufacturer and under no circumstances should
the setting be changed by anyone other than the manufacturer.
Pressure relief valves must be provided to protect compressed air
systems in accordance with ASME B19 safety standards. Failure to
provide properly sized pressure relief valves may cause property
damage, severe personal injury or even death.
Air Intake
A clean, cool and dry air supply is essential to the satisfactory operation of
your Quincy air compressor. The standard air filter that the com pressor is
equipped with when leaving the factory is of sufficient size and design to meet
16