Service And Maintenance; Priming Pump; Control Box - Testing The Gfci - Speck pumps Badu Stream II Manual De Operación Y Servicio

Sistema de nado contra corriente
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Getting Started - continued
NOTE: Under certain conditions it is possible that the
current "drifts o " to the left or the right from the middle
due to water bouncing o the back wall. In the event that
it interferes with your swimming action, turn the unit OFF
for a few minutes and restart.
3

Service and Maintenance

Priming Pump

The BaduStream system comes with a 4 HP self-priming pump (Speck Model 21-80/33 GS) to specifically work with the
swimjet system. The Model 21-80/33 GS self-priming pump has the ability to remove air from the plumbing lines when
installed above the water level (up to 4 feet). During the initial startup, the pump must be filled with water. You should never
run the pump dry for extended periods of time.
Before starting the pump for the first time (or after losing prime),
remove the red filler plug. Fill the pump body with water (approx.
2 gallons) until the water is level with the suction inlet. Replace
the red filler plug, hand tighten, making sure the o-ring is not
damaged. Due to the large amount of air that can be trapped in
the vertical portion of the suction line above the water level,
initial priming time may be longer than with regular pool filtration
pumps. It may take up to ten (10) minutes. This will not damage
the mechanical seal. If prime is not achieved in ten (10) minutes,
stop the pump, re-fill the pump body and restart.

Control Box - Testing the GFCI

WARNING: Before each use, the GFCI located on the side of the control box must be tested.
1. Press the RESET button on the GFCI. The GREEN "power" LED
should be ON.
2. Press the TEST button: GREEN LED should turn OFF. RED LED
should start blinking. Circuit breaker should trip to OFF position.
3. If sensing module LEDs DO NOT change or circuit breaker
DOES NOT trip, DO NOT USE THIS DEVICE. Consult a qualified
electrician for assistance.
4. Press RESET button: RED LED should turn OFF and GREEN LED
should turn ON.
5. MANUALLY RESET circuit breaker to ON position to restore
circuit power.
8
Fill Plug
Figure 2 - The Speck Model 21-80/33 GS (US Motor)
Figure 3 - Control Box

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido