power supply controller.
STEP 1
a.
Use mounting brackets
provided to fix power
supply controller in upright
position.
b.
The power supply
controller and transformer
should always be installed
in a sheltered position ie.
filter housing etc. Must be
away from possible water
splashing e.g. pump lid or
other sources. Never lay
power supply controller or
the transformer flat on the
ground.
STEP 2
* It is recommended that
a registered electrician
CONNECTS the transformer.
Connect the 12/18 Volt cable to
the 12/18 Volt transformer supplied
with chlorinator.
a.
Ensure that transformer
input and output wires face
downward not sideward or
upward. The transformer
must be connected to
a continuous supply
and not be switched via
pump timer (mono units).
Self-cleaning units can
be connected by the
timer
10.
Transformer
1V/18V
1V/18V power
supply controller
cable
Pipe Clip held in posi-
tion with PVC Cement
Wall or pipe mount-
ing bracket for Power
Controller
Transformer cover
Power supply
controller
Cell
cable