6 USE
Press the
(ON) key to activate controls and to switch on the display lighting. The
display lighting switches off 60 seconds after the last command given (adjustable
default time – see "BkLight Time").
(UP) to control the anchor ascending
Press key
(DOWN) to cast anchor
Press key
When any key is released (UP or DOWN) the corresponding action is stopped.

7 TROUBLESHOOTING

FAULT
V=11.6 Vdc
V= 7.9 Vdc

8 WIRING DIAGRAM

10
V=11.6 Vdc
V=11.6 Vdc
CAUSE
Though UP or DOWN keys
are pressed, the instrument
doesn't receive any signal from
the magnetic sensor for more
than 5 seconds.
The instrument's power
supply voltage is lower than10Vdc.

6.1 Measurement reset

To
reset
simultaneously press the
(UP) keys for at least three seconds.
Measurement reset may also be performed
in the Measurement menu by selecting
"Yes" in the Reset Measure row.
Measure
O f f
R e s e t M e a s u r e
U n i t s
E x i t
CORRECTIVE ACTION
Check the sensor electric connections.
Check if sensor operates properly.
If not, replace it.
Check the position of sensor and magnet on
gipsy and their distance (3 mm).
Check the operation of electric
installation or anchor windlass.
Verify the battery charge or
operation of the electrics system.
IRIS
the
measurement
count
(ON) and the
N o
F e e t

Publicidad