5.7 Sensor calibration menu
Once the "Sensor Detection" function has recognised a "Standard" type sensor instead of a "Project" sensor, when
the "Sensor Calibrat." menu is entered again, the menu options will "configure" themselves according to the sensor
detected.
Standard and X.. Project series sensor menu
(magnet and sensor placed on barbotin)
Barbotin Circumference
In this row the user must enter the circumference of the
gipsy (in centimetres or inches).
Use the Table 1 provided to calculate the circumference.
Settable values: centimetres or inches.
Default value, 33 cm.
Select with
Select value with
Confirm with
Exit
To return to the settings menu.
5.8 Table 1 - Standard and Project X.. series sensor
(magnet and sensor placed on barbotin)
Chain type
6 mm
7 mm
8 mm
10 mm
12 mm
13 mm
14 mm
3/8" BBB
3/8" HT
5/16" HT
1/2" BBB
1/2" HT
* factory setting of instrument
8
Use the
Sensor Selection
Press
or
Confirm with
Number of recesses
9
6
6
7
8
5
6
5
6
6
5
7
6
7
6
5
(DOWN) or
(UP) key to move around the parameters
1000 – 1500 –2000 W Project series sensor menu
(magnet and sensor placed on motor)
Reduction Factor
In this row the user must enter the reduction factor.
See next Table 2 for the correct value to be entered
Default value, 57.
Confirm with
Gipsy Circumference (cm)
34
25
28
33*
38
31
36
36
43
46
42
38
37
36
40
40
Select with
Sensor Selection
STD
PROJ
Gipsy Circumference inches)
13
9
11
13
15
12
14
14
17
18
16
15
14
14
16
16
IRIS