ENGLISH
OPERATING INCIDENTS
The suction cup does not adhere to the
component.
Deficient aspiration, Vacuum.
1 Verify if the suction cup is well placed and in
perfect condition.
2 Check the incoming air filter in the interior of
the station and replace it if dirty or obstructed.
Filter
Ref. 0861800
Error messages
ERROR
Whenever the ERR message appears, the
equipment turns itself off completely.
The following messages are displayed:
- BLANK SCREEN
Power failure.
Check for blown fuses.
- ERR 1
The temperature will not rise.
Possible causes:
· Heating element open.
· In case of a long low-power period.
x
- ERR 3
No reading from the thermocouple.
Possible cause: open thermocouple.
- ERR 6
Insufficient air flow which causes an excesive
rise of the heating temperature.
Before recuperating this type of error you
must wait until the temperature goes down.
Possible causes: leaking or blocked air
conducts or faulty self-contained air pump.
- ERR 8
Faulty reading of the rotationsmeter of the
self-contained air pump.
Possible causes: air pump damaged or faulty
function of the optical sensor circuit.
To reset any of these errors turn on the general
switch at the back of the station, the pedal
should not be pushed at this moment.
JBC reserves the right to make technical changes without prior
notification.