Descargar Imprimir esta página

Grohe Blue Ultra Pure 31 312 Manual De Instrucciones página 4

Ocultar thumbs Ver también para Blue Ultra Pure 31 312:

Publicidad

Idiomas disponibles

Idiomas disponibles

Application
Operation is possible in conjunction with:
• Pressurized storage heaters
Operation is not possible with:
• Low-pressure storage heaters (displacement water heaters)
The filter head is fitted with a type-tested check valve.
The water filtrate is classified as Category 2 according
to EN 1717.
Safety notes
Avoid danger due to damaged power cords. In the
case of damage, the control unit must be replaced by
the manufacturer or his customer service department
or an equally qualified person.
• For hygiene reasons, the filter system must be flushed
before using for the first time.
• The filter system must always be operated with cold water
of foodstuff grade.
• The filter head must be replaced after 5 years.
• The control unit and plug must not be directly or indirectly
sprayed with water when cleaning.
• The control unit must be connected to a permanent power
supply.
• At the installation location, the filter system must be
protected against mechanical damage, heat and direct
sunlight.
Do not install near heat sources or an open fire.
• Installation of the fitting with filter cartridge is only permitted
in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty.
Specifications
Electrical data:
• Voltage supply:
• Power consumption:
• Standby power loss:
• Type of protection
– Control unit:
– Mains plug:
Sanitary data:
• Flow pressure:
– min.
– recommended
• Operating pressure
– Fitting:
– Filter cartridge and filter head:0.2 – 0.8 MPa (29 – 116 psi)
• Test pressure of fitting:
If static pressures exceed 0.5 MPa (72 psi), a pressure-
reducing valve must be installed.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 0.3 MPa (43 psi) flow pressure
– Fitting (tap water):
– Filter cartridge (GROHE Blue
1
English
100 - 240 V AC / 50/60 Hz
9 W
< 1.0 W
IP 68
IP 40
0.1 MPa (14.5 psi)
0.2 – 0.5 MPa (29 – 72 psi)
max. 0.8 MPa (116 psi)
1.6 MPa (232 psi)
approx. 2.4 gallons
®
water): approx. 1.2 gallons
• Ambient temperature:
• Temperature
– Hot water inlet:
– Recommended (energy saving):
• Adjustable bypass, factory setting:
• Filter capacity at 40% bypass
(Carbonate hardness 14 - 17 °KH):
• Water connection:
Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Electrical installation
Electrical installation work must only be
performed by a qualified electrician. This work
must be carried out in accordance with the
regulations according to IEC 364-7-701-1984
(corresponding to VDE 0100 Part 701) as well
as all national and local regulations.
Installation
Refer to the dimensional drawings on fold-out page I.
Install fitting, see fold-out page II, Figs. [1] and [2].
Important: The cable must not be pinched.
Flush piping system prior and after installation of faucet
thoroughly!
Install filter cartridge, see Figs. [3] to [5].
The filter head can be swivelled forwards by up to 90° in the
wall holder to install the cartridge.
Use suitable screws and, if required, plugs.
Install control unit, see Figs. [6] and [7].
Important: Do not connect voltage supply yet.
Connect fitting, see Figs. [2], [8] to [10].
Open hot and cold water supply and check that
connections are watertight.
Connect voltage supply via mains plug, see Fig. [11].
The display illuminates and the remaining filter capacity is
displayed in per cent.
39 – 90 °F
max. 158 °F
140 °F
30%
max. 160 gallons
corresponds to max. 12 months
cold - blue
hot - red
A
2
2,500 V
212 °F

Publicidad

loading

Este manual también es adecuado para:

Blue ultra pure 33 313Blue ultra pure 31 313