Descargar Imprimir esta página

Grohe Blue Ultra Pure 31 312 Manual De Instrucciones página 6

Ocultar thumbs Ver también para Blue Ultra Pure 31 312:

Publicidad

Idiomas disponibles

Idiomas disponibles

Warning
Risk of damage:
Always disconnect the power supply before performing
maintenance work on the system. The plug-in connectors
can then be disconnected, see fold-out page II, Fig. [7].
Inspect and clean all components and replace if necessary.
I. Cartridge, see fold-out page III, Fig [15].
Assemble in reverse order. When installing the cartridge,
ensure that the seals are correctly seated. Replace screw
coupling and tighten.
II. Headpart, see fold-out page III, Fig. [16].
Assemble in reverse order. Note the installation position of the
stop.
III. Mousseur (64 374), see fold-out page I.
Assemble in reverse order.
Fault
Cause
Water not flowing
• Water supply interrupted
Filtered water not
• Water supply interrupted
flowing
Display in handle
• No connection between fitting
does not illuminate,
and control unit
E3 flashes in display
• Cable or connector faulty
Handle flashes
• No filter capacity
orange, E8 flashes
in the display
E6 or EE flashes
• Conrol unit fault
in the display
Display in handle
• No connection between fitting
illuminates red
and control unit
Indicator lamps
• Control not recognised
do not flash/flash
continuously
Display in handle
• No connection between fitting
does not illuminate
and control unit
or illuminates
continuously
3
English
Service
In order to improve customer service, we recommend
registering the product at www.grohe.com.
Note the Fault / Cause / Remedy table for information on
eliminating problems.
In the event of problems with the settings, please consult
a specialist installer or the GROHE Service Hotline via email
under TechnicalSupport-HQ@grohe.com.
Replacement parts
See fold-out page I (* = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Environment and recycling
Used filter cartridges can be returned to GROHE at the
address for the relevant country, at www.grohe.com.
However, the filter can also be disposed of hazard-free
in domestic waste.
Remedy
- Open shut-off valves
- Establish water supply to fitting
- Attach connectors
- Contact Grohe Service
- Change filter cartridge immediately
- Contact Grohe Service
- Synchronise with one another, see section
Installation
- With mains plug connected, disconnect plug-in
connector, wait 30 seconds and reconnect
- Synchronise with one another, see section
Installation

Publicidad

loading

Este manual también es adecuado para:

Blue ultra pure 33 313Blue ultra pure 31 313