Descargar Imprimir esta página

Fein Slugger JCM125Q Manual Del Usuario página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

3 41 01 165 21 0.book Seite 15 Mittwoch, 7. September 2011 12:05 12
Starting and stopping the drill motor (Figure 8).
Starting:
Switch the motor switch ON (I).
Stopping:
Switch the motor switch OFF (O).
Shutting magnet OFF (O):
Switch off the magnet with the magnet
power switch.
When the power supply is disconnected
while the motor is running, a protective cir-
cuit prevents automatic restarting of the
motor. Restart the motor again.
In case of overload, the motor automatically
stops and must be restarted again.
Feed (Figure 9).
Feed using the spoke handle.
Instructions for core drilling.
Punch-mark the marked drilling location.
Rotate the cutting tool downward until the
pilot pin centers on the punch-mark.
Carefully begin the drilling process until a
groove has been established on the cutting
surface.
Do not stop the drill motor during the
drilling procedure.
Only remove the cutting tool from of the dril-
ling hole while the motor is running.
If the carbide tipped cutter should remain
stuck in the material, stop the drill motor and
carefully turn the carbide tipped cutter out
clockwise.
Fig. 8
Motor switch
Fig. 9
Remove the chips and the slug after each dril-
ling process.
Do not touch the chips with your bare
hand. Always use a chip hook.
When changing a cutting tool, pay attention
not to damage the cutting edges.
When core drilling layered material, use a
Slugger ID sharpened cutter for stack drilling.
en
15
Spoke
handle

Publicidad

loading