Terminal board connections
CMN common for all inputs and outputs.
7
ELS electric lock output (fed continuously) 12 Vdc - 15 W.
8
9-10 LC-CH2 Potential free contact for the activation of the courtesy light
(separate power supply Vmax=30 Vac/dc: Imax=1A) or the second
radio channel. Selection is carried out using jumper "J5".
11
CMN common for all inputs and outputs.
12
LP 24 Vdc 25 W output for warning lights.
intermittent activation (50%), 12,5 W continuous activation
LS 24 Vdc 3 W output for an indicator light.
13
14
CMN common for all inputs and outputs.
15
30 Vdc controlled output, powering external loads
16
CMN common for all inputs and outputs.
17
30 Vdc output, powering external loads
18
CMN common for all inputs and outputs.
TA (NO contact) opening button input
19
TC (NO contact) closing button input
20
21
TAL (NO contact) limited opening button input
22
TD (NO contact) dynamic button input
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
23
CMN common for all inputs and outputs.
24
TB (NC contact) stop button input (The opening of this contact inter-
rupts the cycle until a new movement command is given).
FTCS (NC contact) safety and control devices in input (stop photocells).
25
The opening of this contact will block all movement, until the obstruction
has been removed and the pause time has elapsed, due to the safety
device cutting in, the door will then continue moving in the closing
direction (only with automatic reclosing enabled).
26
FTCI (NC contact) safety and control devices in input (photocells invert
the travel direction when an obstruction is detected). Opening this
contact will provoke a travel direction inversion during closure due to
the cutting in of the safety device.
27
EMRG2 (NO) emergency manoeuvre input 2
28
EMRG1 (NO) emergency manoeuvre input 1
29
CMN common for the emergency buttons
30
Inner conductor for radio receiver antenna (if an external antenna is
fitted use a coaxial type cable RG58 with an impedance of 50Ω).
10
J1
F3
L3
J2
10
Collegamento motori/encoder a 4 fili
Connecting motor/4-wire encoder
Branchement moteur/encodeur à 4 fils
Anschluss der Motor/Encoder mit 4 Drähten
Conexionado motores/encoder de 4 conductores
COLORE
CABLAGGI
Bl
Blu
Gr
Verde
Gy
Grigio
Yw
Giallo
KABELFARBEN
Bl
Blau
Gr
Grün
Gy
Grau
Yw
Gelb
ENCODER 1
M1
Bl
Gr
1
2
3
4
B1
Signal buzzer "via radio" mode
CSER Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
F1
10A blade fuse
(motor power protection)
(5)
F2
10A blade fuse
(5)
(motor protection during battery operation)
F3
4A
blade fuse
(5)
(24V circuit protection)
F4
4A
blade fuse
(24V circuit protection during battery operation)
(5)
F5
4A
blade fuse
(electric lock protection)
(5)
J1
Battery connection
Drawing number :
DC0388
Product Code :
CC242ESBBS
.
(1)
.
(1)
4A
F2
F4
L2
L1
F1
COLOUR CODE COLORATION
CODE
DES CÂBLAGES
Blue
Bleu
Green
Vert
Grey
Gris
Yellow
Jaune
COLORACIÓN
CABLEADOS
Azul
Verde
Gris
F5
Amarillo
ENCODER 2
M2
Gy
Yw
Bl
Gr
Gy
Yw
1
2
3
4
5
6
5
6
Description :
CENTRALINA 2 MOTORI CC CON ENCODER
(con 6 display a led - selezione a dipswitch )
31
Outer conductor for radio receiver antenna
Note
The total of the 2 external device outputs must not exceed 10 W.
(1)
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the
security device test must also be deactivated (FTCI , FTCS - Dip 7 and Dip
8 "OFF") . If you want to activate the FTCI, FTCS test both the transmission
and receiver parts of the security devices must be connected to the binding
post marked "CTRL 30 Vdc". If the test is active there will be a 1 second
delay between the command transmission and movement of the gate/s.
Switch on the power and make sure that the indicator LEDs are in the fol-
lowing condition.
- L1 Power on
- L2 Battery charging
- L3 Wrong battery connection
- L4 Transmitter code programming indicator
- L5 Indicator for the blocking button "TB"
- L6 Indicator for the inverting photoelectric cells "FTCI"
- L7 Indicator for the stop photoelectric cells "FTCS"
- L8 Indicator for the opening button "TA"
- L9 Indicator for the opening button "TC"
- L10 Indicator for the limited opening button "TAL"
- L11 Indicator for the sequential command "TD/CH1"
Note
: This LED is "ON" when the battery is charging.
(2)
Note
: If this LED is "ON" invert the battery power cables immediately.
(3)
Note
: Check that the activation of the safety devices switches the cor-
(4)
responding LEDs off.
If the green power on LED "L1" doesn't light up check the condition of the
fuses and the power cable connection at the transformer primary.
If one or more of the safety LEDs do not light up check the contacts of the
relative security devices and check that the unused safety device contacts
have been bridged.
R1
MM
L5
J3
J4
L6
L7
DS1
P2
TD
RA
L4
PLP
LP
LS
P3
FTCI
TFTI
TFTS
SAP
ELS
LC/CH2
7
8
9
10
11
12
13
14
15
16
J2
Transformer secondary protection
J3
Enable transmitter memorisation via radio
J4
Radio channel selection
J5
Binding posts 9, 10 selection (courtesy light/CH2 via radio)
MM
Transmitter code memory module
P1
Programming button (PROG)
P2
Transmitter code memorization button (MEMO)
P3
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
Note
: These are automotive type blade fuses (max. voltage 58 V)
(5)
Collegamenti scheda base
19
CS 1218 DC0355
B1
L8
L10
P1
D1
L9
L11
CSER
J5
1 2
1 2
3
3
Pos.1
Pos.2
CMN
EMRG 1
EMRG 2
21
24
25
17
18
19
20
22
23
ON
OFF
(2)
OFF
(3)
OFF
ON
(4)
ON
(4)
ON
(4)
OFF
OFF
OFF
OFF
26