To Set the Static Correction Level

Note: Your Receiver Collar has been factory-set to Beep Only.
Read all the steps below before attempting to set
the Static Correction Level. Refer to the Function
and Response Table below for advice on setting the
Static Correction Level that best suits your pet.
1. Remove the clear plastic cover with a coin to
expose the Correction Level Button (2F).
2. With the battery installed, press the Correction
Level Button and release when the Receiver
LED Indicator Light lights up (2G).
3. The Receiver LED Indicator Light will emit
a series of fl ashes corresponding to the Static
Correction Level.
4. Increase the Static Correction Level by pressing
and releasing the Correction Level Button within
5 seconds of the previous series of fl ashes.
5. After setting the Static Correction Level, replace
the cover to protect the Correction Level Button.
The Static Correction levels increase in strength from 1 to 6. Pushing the Correction Level Button while the
Receiver Collar is on level 6 will cause the Receiver Collar to revert to level 1. Refer to the Function and Response
Table to choose the Static Correction level that best fi ts your pet.
The Receiver LED Indicator Light acts as a low battery indicator, fl ashing every 4 to 5 seconds when replacement
is required.

Function and Response Table

Indicator Light
Response
1 Flash
2 Flashes
3 Flashes
4 Flashes
5 Flashes
6 Flashes
Flashes once every
4 to 5 seconds
Note: Begin training with Static Correction Level 2 and only increase if your pet does not respond to the Static Correction.
__________________________________________________

Adjust the Pet Area to Desired Size

Step
3
Make sure the entire Pet Area lies within your property boundaries (3A). Always start
determining the Boundary Zone at the shortest distance from Transmitter. Place the
Boundary Switch on "High" for Boundary Zones more than 13.5 m (45 ft) from the
Transmitter. For Boundary Zones below this distance place the Boundary Switch on "Low."
Two-Person Method
Hold the Receiver Collar at your pet's neck height (3B) with the Petsafe logo facing away
from the Transmitter (3C). Walk to the edge of the desired Pet Area. Facing away from the
Transmitter, hold the Receiver Collar at the edge of the desired Pet Area (3D).
Starting with the Boundary Control Dial set to "8", have a second person turn the dial
down SLOWLY. When the Receiver Collar starts to beep, tell the person to stop turning
the Boundary Control Dial. Record your settings below for future reference.
6
Static
Receiver Collar Function
Correction Level
1
No Static Correction, Beep Only
2
Low Static Correction
3
Medium-Low Static Correction
4
Medium Static Correction
5
Medium-High Static Correction
6
High Static Correction
Indicates Low Battery
www.petsafe.net
Temperament of Pet
Timid
Timid or Average
Average Energy
Average or High Energy
High Energy
3A
Pet
Area