One-Person Method
Measure the shortest distance from the
desired Boundary Zone to the Transmitter.
Place the Boundary Switch on "High" for
Boundary Zones more than 13.5 m
(45 ft) from the transmitter and on "Low"
for Boundary Zones below this distance.
Then set the Boundary Control Dial
according to the Transmitter Range Chart
below. Take the Receiver Collar to the
Boundary Zone with the Receiver Collar
at your pet's neck height (3B) with logo
side facing away from the Transmitter (3C). Determine where the Receiver Collar begins to beep. If the Receiver Collar beeps
before or after the desired Boundary Zone, return to the Transmitter and adjust the Boundary Control Dial. Repeat this process
until the Receiver Collar is beeping at the desired location. Record your settings below for future reference.
Note: If you cannot hear the beep, refer to the "Test Light Instructions" section.
Transmitter
Range Chart
Boundary
Control
Dial
Position
1
2
3
4
5
6
7
8
Note: These distances are approximate.

Place the Boundary Flags

Step
4
The Boundary Flags are visual reminders for your pet of where the Boundary Zone is located. The Receiver
Collar will activate within 0.6 to 1 m (2 to 3 ft) of the Boundary Flags.
1. Hold the Receiver Collar at your pet's neck height with the PetSafe logo facing away from the Transmitter.
2. Walk towards the Boundary Zone until the Receiver Collar beeps (4A).
3. Place a Boundary Flag in the ground (4B).
4. Walk back into the Pet Area until the beeping stops.
5. Repeat this process around the Boundary Zone until it is marked with
Boundary Flags every 3 m (10 ft).
The Boundary Flags may be in different parts of the Boundary Zone and
may not be in a line. The Boundary Zone is 0.6 to 1 m (2 to 3 ft) wide.
Note: If you cannot hear the beep, refer to the "Test Light Instructions" section.
3B
Boundary
Boundary
Switch
Switch
LOW
HIGH
1.5–3 m
1.5–3 m
(5-10 ft)
(5-10 ft)
1.5–3 m
1.5–3 m
(5-10 ft)
(5-10 ft)
4.5–6 m
7.5–10.5 m
(15-20 ft)
(25-35 ft)
6–7.5 m
12.5–16.5 m
(20-25 ft)
(42-55 ft)
7.5–9 m
16.5–19.5 m
(25-30 ft)
(55-65 ft)
10.5–12 m
23–26 m
(35-40 ft)
(75-85 ft)
12–13.5 m
26–27.5 m
(40-45 ft)
(85-90 ft)
12–13.5 m
26–27.5 m
(40-45 ft)
(85-90 ft)
3C

Record Your Settings

Final Bound-
ary Switch
Setting
(HIGH or
LOW)
Home
Camping
Vacation
Other
www.petsafe.net
3D
Boundary
Final
Boundary
Control Dial
Position
(1-8)
4A
4B
Pet
Area
Zone
Receiver
Static
Correction
Level (1-6)
7