PCM100 / PCM130 - User Manual
3.7

Remote-control receiver setup

Visualization of the programmed code
Keep pressed P1 and P2 buttons (page 21 and 22) for at least 2 seconds and not more
than 5 seconds, up to the two LEDs (page 21 and 22) light on.
Pressing the P1 button it will be displayed the 12-bit code of "A" channel by a sequence of
blinkings of the LEDs:
one blink of LED button P1(page 21 and 22)indicates dip switch ON
one blink of LED button P2(page 21 and 22) indicates dip switch OFF
At the end of the sequence, it will exit automatically the setup mode.
NOTE: If no buttons is pressed in 5 seconds, the produre is stopped and no code will be
displayed.
NOTE: To visualize the code of the "B" channel, repeat the same procedure using the P2
button.
Auto-learning of the remote-control code
Keep pressed P1 and P2 buttons (page 21 and 22) for at least 5 seconds up to the two
LEDs start to blink (LED button P1 and LED button P2 at page 21 and 22).
Press P1 button, only LED LED button P1 starts to blink.
During the blinking, within 5 seconds press the "A" button of the remote-control to let
acquire the code.
The LED button P1 starts a sequence of blinkings to indicate that the code has been
acquired and it will exit automatically the setup mode.
NOTE: If no remote-control is activated in 10 seconds, the setup is stopped and no code will
be programmed.
NOTE: For the acquisition of the code of the channel "B" of the remote-control, repeat the
procedure using P2 buttons and LED LED button P2.
Summary of setup accessing times
Time of simultaneous pressure of P1 e P2 buttons:
LED Status
Function
30
0 sec.
LED "1" and "2"
turn off
No action
2 sec.
LED "1" and "2"
light
Release P1 and P2
buttons to enter in Code
Display Mode.
5 sec.
LED "1" and "2"
blink
Release P1 and P2
buttons to enter in
Auto-acquisition Code
Mode

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pcm130

Tabla de contenido