Hardware Included - Dura Heat EWH5500 Instrucciones De Instalación Y El Manual De Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model No
Volts/Hertz
EWH5500
240V/60HZ
EWH9600
240V/60HZ
To prevent a possible fire, injury to persons or damage to the heater, adhere to the following:
1. Disconnect all power coming to heater at main service panel before wiring or servicing.
2. All wiring procedures and connections must be in accordance with the National and Local Codes having
jurisdiction and the heater must be grounded.
3. Verify the power supply voltage coming to heater matches the ratings as shown on the heater
nameplate.
CAUTION: ENERGIZING HEATER AT A VOLTAGE GREATER THAN THE VOLTAGE PRINTED ON THE
NAMEPLATE WILL DAMAGE THE HEATER AND VOID THE WARRANTY AND COULD CAUSE A FIRE.
4. CAUTION: High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other
combustibles at least 3 feet (0.9 m) from front of heater. Do not install heater behind doors, below towel
racks, or in an area where it is subject to being blocked by furniture, curtains or storage materials. Hot air
from the heater may damage certain fabrics and plastics.
5. To reduce the risk of fire do not store or use gasoline or other flammable vapors and liquids in the
vicinity of the heater.
6. When heater is to be wall or ceiling mounted, the anchoring provision must be sufficient strength to
support the total weight of the heater plus the weight of the mounting provisions. Failure to properly
secure the supporting members of the building structure could allow the heater to fall.
7. The following minimum clearances must be maintained: 30° Tilted, Bottom of Heater to Floor: 6' (1.8
M) minimum, 11' (3.3 M) recommended maximum Horizontal Airflow, Bottom of Heater to Floor: 6' (1.8
M) minimum, 8' (2.4 M) recommended maximum Side of heater to adjacent wall: 6" (13 mm)
8. Do not use this heater for drying out paint, plaster, sawdust and drywall sanding dust as this
will permanently damage the heater and must be kept out of the heater.
Unpacking Your New Heater: Remove heater from box, locate parts bag in packing material, and inspect
to make sure heater is not damaged or missing parts. If damaged or parts are missing, call our Technical
Service Hotline at 1-800-776-9425 for assistance. Do not return to store where purchased until you first
call the above number for assistance.
HARDWARE INCLUDED: Figure 1
SPECIFICATIONS
(All Specifications -5%/-10% tolerance)
Amps
21
42
Watts
BTU/HR
5000
17060
10000
34120
Phase
Minimum
Circut
1
30
1
50

Publicidad