Technical Data

q
Input voltage:
Max. permissible load:
Display range in volts:
Display range in amperes:
Display range in watts:
Display range Kilowatt hour:
Display range power costs:
Display range line frequency: 45 – 65 Hz
Lower range limit for
Load display:
Clock display:
Temperature range:
22 GB
Steckdosenleiste_Content_DE_GB_NL_SE_ES.indd 22
Time
Current in volts
Current strength in amperes
Power consumption in watts
Maximum power consumption in watts
Power consumption in kilowatt hours
"set"
Cost per kilowatt hour
Max. Overload value
Warning! Overload value exceeded
Total price of energy used
Total price for energy used at rate 1
Total price for energy used at rate 2
CO2-emissions in kilograms
Power factor
Frequency in hertz
AM
PM
Total on time
230 V ~ , 50 Hz
16 A, 3680 W
200 – 276 V ~ ± 1.5%
0.0005 – 16 A ± 1.5%
0.1 – 3680 W ± 1.5%
0.00 – 9,999.9 kWh
0.00 – 9,999
0.5 W
± 1 Minute per Month
-10 - +40 °C
23.07.14 13:23