The control panel is located in the center of the hood bottom.
Warning: Do NOT force the control dial to turn beyond its limit.
Function
Lights - Dimmer
Lights - High
Lights - Off
Speed 1
Speed 2
Speed 3
Intensive Speed (motor
turns off after 10
minutes of operation)
Turn the motor off
Delay auto shut off
Heat Sensor Active
Heat Sensor Inactive
Heat Sensor Fault
Heat Sensor Features
Heat Sensor Faults
USE AND CARE INFORMATION
Rangehood Control Panel
B0
Operation
Press the button once to turn the lights on dimmer (B2)
Press the button a second time to turn the lights on high (B2)
Press the button a third time to turn the lights off (B2)
Quick turn of the knob to the right (1st time) (B1)
Quick turn of the knob to the right (2nd time) (B1)
Quick turn of the knob to the right (3rd time) (B1)
Quick turn of the knob to the right (4th time) (B1)
While at any speed, hold the knob for 2 seconds to the left to
turn the motor off. Alternatively, a quick turn of the knob to the
left backwards thru the speeds (1 turn to the left past speed
1) , turns the motor off. (B0)
Hold the knob to the right for 2 seconds. The hood and lights
stay on for 10 minutes, then turn off. (B1)
Press button for 2 seconds (B2)
Press button for 2 seconds (B2)
If the motor is off and the temperature gets to approximately
130 degrees F (55 degrees C°)– the blower turns on speed
2 for a minimum of 15 minutes. Once the temperature has
dropped below 130 degrees F (55 degrees C°), the motor
turns off. If you operate the hood manually during this
function, the auto on sensor is disabled for 15 minutes.
If the temperature remains too high, the blower remains on
for up to 90 minutes until the temperature has dropped below
130 degrees F (55 degrees C°).
B1
B2
LED Color / Light Pattern
Green - Solid
Yellow - Solid
Red - Solid
Red - Blinking
No Color
The selected speed blinks
Red Blinking One time
Red Blinking Three times
Purple blinking
Red - Blinking
Red - Blinking