The wire which is coloured Green-and-Yellow must
be connected to the terminal in the plug which is
marked with the letter E or by the symbol
coloured Green or Green-and-Yellow. The wire
which is coloured Blue must be connected to
the terminal which is marked with the letter N or
coloured Black. The wire which is coloured Brown
must be connected to the terminal which is marked
with the letter L or coloured Red.
* Should the socket outlets in the installation site not
be suitable for the plug supplied with your product,
the plug must be removed (cut off if it is moulded
on plug) and an appropriate plug fitted.
If the non-rewirable plug has been cut from the
power supply cord, it must be disposed of. There
should be no attempt to reuse it. Inserting such a
plug into a socket elsewhere presents a serious
risk of electrical shock.
* The non-rewirable plug must never be used
without a fuse cover being fitted.
The correct replacement for the detachable fuse
cover is identifiable from the manufacturer 's
reference number stamped on the plug.
Supply of replacement fuse covers can be
obtained from Hoshizaki Parts/Service Centres.
Fuses should be rated at 13A and approved to BS
1362.
5. WATER SUPPLY AND DRAIN
CONNECTIONS
WARNING
Connect to potable water supply only.
* The connections to the mains water supply must
be made in accordance with the countries' current
requirements of the Water Supply or Water Fittings
Regulations.
* Icemaking water must be potable water. Where
scaling can be caused by water quality, installation
of an external filter or softener is recommended.
Contact your local water treatment professional or
Hoshizaki service agent.
* Water supply pressure should be minimum 0.05
MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
If the pressure exceeds 0.8 MPa (8 bar), use a
proper pressure reducing valve. Do NOT throttle
back the supply tap.
* A plumbing permit and services of a licensed
plumber may be required in some areas.
or
* The icemaker drain is gravity flow, so ensure drain
pipe has an adequate pitch or fall.
* Water should drain into an open trap.
1) Attach angled end of white flexible inlet hose
(accessory) to the G3/4 fitting at the top rear of the
icemaker as indicated, ensuring rubber sealing
washer is correctly positioned. Hand tighten
sufficiently to provide leak free joint.
2) Attach the other end of inlet hose to the water tap,
noting washer is correctly positioned before hand
tightening as above.
3) Attach grey flexible outlet hose (accessory) to the
R3/4 fitting at the bottom rear of the icemaker as
indicated, confirming fitment of rubber washer
before finally hand tightening the joint. This pipe
can be cut to length as necessary to suit position
of main drain.
Inlet Hose
Outlet Hose
3
ENGLISH
Water Supply
Inlet G3/4
Drain Outlet
R3/4
Fig. 3
Water Supply Tap
Inlet Hose
Fig. 4