4
Electrical installation
Design including a connector
Power terminals
6-pole (external view of poles)
Pin
Standard description
1
BD1
2
BD2
PE
4
U
5
V
6
W
MCA 19...21, MCS 14...19, MQA 20 (external view of poles)
Pin
Standard description
1
Not assigned
2
+
BD1
-
BD2
PE
U
U
V
V
W
W
*
At times, older documents also stated plug sizes of 1.0 (M23) and 1.5 (M40).
26
Meaning
Holding brake +
Holding brake -
PE conductor
Power phase U
Power phase V
Power phase W
Meaning
Holding brake +
Holding brake -
PE conductor
Power phase U
Power phase V
Power phase W
M23
M40
ASPL 33.0006 DE/EN/FR/ES/IT 2.0